Features
Save energy from the heating & cooling of your place and the immediate hot water production
Benefits
Wi-Fi Standard
Through the smart Wi-Fi management, you get to create the environment you desire, from anywhere. Free download the Comfort Home app from Google Play or App Store and save energy operating your appliance through your smartphone or tablet.
Compressor and Chassis Heating Belt
The heat pump units are designed with pre-installed heating belts located on the chassis and the compressor to ensure their protected operation even at extreme weather conditions, a longer operation life, and provide high efficiency and stellar heating conditions quickly and effectively.
Modular Connection of up to 6 Units in the same Water Circuit
Inventor monoblock type heat pumps are equipped with modular technology allowing to connect up to 6 units to the same water circuit to be operated from a single wired controller, while the unit settings can be achieved easy and faster due to the easy addressing technology.
2 Stage Silent Mode
Reduce the heat pump noise levels even further by selecting between the two different levels of silent operation.
Disinfection Function 65~70⁰C
Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.
Fast Domestic Hot Water Function
You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.
All DC Inverter
With the inclusion of All DC Inverter technology, Inventor heat pumps operate at the ideal settings according to the constantly changing consumption needs, operating at the lowest possible noise levels while at the same time saving energy.
Priority Function
You can select the operation priority of the heat pump. The heat pump will prioritize DHW production or space heating & cooling according to your needs.
Smart Grid Ready
Designed as environmental friendly, Inventor heat pumps can connect with a Smart City’s Smart Grid. Through their connection with the Smart Grid, the heat pumps can automatically alter their operation to activate the DHW production when there is excess energy available or to restrict their operation when the electricity grid is overtaxed, saving energy and helping protect the environment.
Floor Protection
Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.
Technical Specifications
- ATS04S/
HU100WT190S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 4.25 kW
- Rated input 0.82 kW
- COP 5.20
- Water temperature 55°C
- Capacity 4.4 kW
- Rated input 1.49 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 4.5 kW
- Rated input 0.81 kW
- EER 5.55
- Water temperature 7°C
- Capacity 4.7 kW
- Rated input 1.36 kW
- EER 3.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 191
- class A+++
- Water outlet at 55⁰C
- ηs (%) 129.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.85
- Water outlet at 55⁰C 3.31
- SEER
- Water outlet at 7⁰C 4.98
- Water outlet at 18⁰C 7.77
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/12 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 56/44/39 dB(A)
- Indoor 38/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 58/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS04S/
HU100WT240S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 4.25 kW
- Rated input 0.82 kW
- COP 5.20
- Water temperature 55°C
- Capacity 4.4 kW
- Rated input 1.49 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 4.5 kW
- Rated input 0.81 kW
- EER 5.55
- Water temperature 7°C
- Capacity 4.7 kW
- Rated input 1.36 kW
- EER 3.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 191
- class A+++
- Water outlet at 55⁰C
- ηs (%) 129.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.85
- Water outlet at 55⁰C 3.31
- SEER
- Water outlet at 7⁰C 4.98
- Water outlet at 18⁰C 7.77
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/12 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 56/44/39 dB(A)
- Indoor 38/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 58/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS06S/
HU100WT190S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 6.2 kW
- Rated input 1.24 kW
- COP 5.0
- Water temperature 55°C
- Capacity 6.0 kW
- Rated input 2.03 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 6.55 kW
- Rated input 1.34 kW
- EER 4.9
- Water temperature 7°C
- Capacity 7.0 kW
- Rated input 2.33 kW
- EER 3.00
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 195
- class A+++
- Water outlet at 55⁰C
- ηs (%) 137.9
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.95
- Water outlet at 55⁰C 3.52
- SEER
- Water outlet at 7⁰C 5.31
- Water outlet at 18⁰C 8.25
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/14 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 58/45/40 dB(A)
- Indoor 38/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 58/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS06S/
HU100WT240S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 6.2 kW
- Rated input 1.24 kW
- COP 5.0
- Water temperature 55°C
- Capacity 6.0 kW
- Rated input 2.03 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 6.55 kW
- Rated input 1.34 kW
- EER 4.9
- Water temperature 7°C
- Capacity 7.0 kW
- Rated input 2.33 kW
- EER 3.00
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 195
- class A+++
- Water outlet at 55⁰C
- ηs (%) 137.9
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.95
- Water outlet at 55⁰C 3.52
- SEER
- Water outlet at 7⁰C 5.31
- Water outlet at 18⁰C 8.25
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/14 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 58/45/40 dB(A)
- Indoor 38/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 58/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS08S/
HU100WT190S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 8.3 kW
- Rated input 1.6 kW
- COP 5.2
- Water temperature 55°C
- Capacity 7.5 kW
- Rated input 2.36 kW
- COP 3.18
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 8.4 kW
- Rated input 1.66 kW
- EER 5.05
- Water temperature 7°C
- Capacity 7.4 kW
- Rated input 2.19 kW
- EER 3.38
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 205.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 131.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.22
- Water outlet at 55⁰C 3.36
- SEER
- Water outlet at 7⁰C 5.83
- Water outlet at 18⁰C 8.95
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/16 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 59/46/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 75/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS08S/
HU100WT240S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 8.3 kW
- Rated input 1.6 kW
- COP 5.2
- Water temperature 55°C
- Capacity 7.5 kW
- Rated input 2.36 kW
- COP 3.18
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 8.4 kW
- Rated input 1.66 kW
- EER 5.05
- Water temperature 7°C
- Capacity 7.4 kW
- Rated input 2.19 kW
- EER 3.38
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 205.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 131.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.22
- Water outlet at 55⁰C 3.36
- SEER
- Water outlet at 7⁰C 5.83
- Water outlet at 18⁰C 8.95
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/16 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 59/46/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 75/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS10S/
HU100WT190S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 10.0 kW
- Rated input 2.0 kW
- COP 5.0
- Water temperature 55°C
- Capacity 9.5 kW
- Rated input 3.06 kW
- COP 3.1
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 10.0 kW
- Rated input 2.08 kW
- EER 4.8
- Water temperature 7°C
- Capacity 8.2 kW
- Rated input 2.48 kW
- EER 3.3
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 204.8
- class A+++
- Water outlet at 55⁰C
- ηs (%) 136.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.2
- Water outlet at 55⁰C 3.49
- SEER
- Water outlet at 7⁰C 5.96
- Water outlet at 18⁰C 8.8
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/17 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 60/49/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 75/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS10S/
HU100WT240S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 10.0 kW
- Rated input 2.0 kW
- COP 5.0
- Water temperature 55°C
- Capacity 9.5 kW
- Rated input 3.06 kW
- COP 3.1
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 10.0 kW
- Rated input 2.08 kW
- EER 4.8
- Water temperature 7°C
- Capacity 8.2 kW
- Rated input 2.48 kW
- EER 3.3
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 204.8
- class A+++
- Water outlet at 55⁰C
- ηs (%) 136.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.2
- Water outlet at 55⁰C 3.49
- SEER
- Water outlet at 7⁰C 5.96
- Water outlet at 18⁰C 8.8
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/17 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 60/49/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 75/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS12S/
HU160WT240S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 12.1 kW
- Rated input 2.44 kW
- COP 4.95
- Water temperature 55°C
- Capacity 11.9 kW
- Rated input 3.87 kW
- COP 3.05
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 12.0 kW
- Rated input 3.0 kW
- EER 4.0
- Water temperature 7°C
- Capacity 11.6 kW
- Rated input 4.22 kW
- EER 2.75
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 189.4
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.1
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.81
- Water outlet at 55⁰C 3.45
- SEER
- Water outlet at 7⁰C 4.93
- Water outlet at 18⁰C 7.14
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 30/25 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x6.0 / 2x25 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 64/50/43 dB(A)
- Indoor 42/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 97/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS14S/
HU160WT240S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 14.5 kW
- Rated input 3.09 kW
- COP 4.70
- Water temperature 55°C
- Capacity 13.8 kW
- Rated input 4.60 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 13.5 kW
- Rated input 3.74 kW
- EER 3.61
- Water temperature 7°C
- Capacity 12.7 kW
- Rated input 4.98 kW
- EER 2.55
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 185.7
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.81
- Water outlet at 55⁰C 3.45
- SEER
- Water outlet at 7⁰C 4.81
- Water outlet at 18⁰C 6.86
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 30/26 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 65/51/43 dB(A)
- Indoor 44/25 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 97/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS16S/
HU160WT240S3 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 16.0 kW
- Rated input 3.56 kW
- COP 4.50
- Water temperature 55°C
- Capacity 16.0 kW
- Rated input 5.52 kW
- COP 2.85
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 14.2 kW
- Rated input 3.94 kW
- EER 3.61
- Water temperature 7°C
- Capacity 14.0 kW
- Rated input 5.71 kW
- EER 2.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 181.7
- class A+++
- Water outlet at 55⁰C
- ηs (%) 133.3
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.72
- Water outlet at 55⁰C 3.47
- SEER
- Water outlet at 7⁰C 4.6
- Water outlet at 18⁰C 6.67
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 30/27 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 68/54/43 dB(A)
- Indoor 44/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 97/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS12T/
HU160WT240T9 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 12.1 kW
- Rated input 2.44 kW
- COP 4.95
- Water temperature 55°C
- Capacity 11.9 kW
- Rated input 3.87 kW
- COP 3.05
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 12.0 kW
- Rated input 3.00 kW
- EER 4.0
- Water temperature 7°C
- Capacity 11.6 kW
- Rated input 4.22 kW
- EER 2.75
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 189.3
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.1
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.72
- Water outlet at 55⁰C 3.47
- SEER
- Water outlet at 7⁰C 4.83
- Water outlet at 18⁰C 7.0
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9/3 kW/Ph
- MOP/MCA 14/10 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 64/50/43 dB(A)
- Indoor 42/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 112/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS14T/
HU160WT240T9 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 14.5 kW
- Rated input 3.09 kW
- COP 4.7
- Water temperature 55°C
- Capacity 13.8 kW
- Rated input 4.6 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 13.5 kW
- Rated input 3.74 kW
- EER 3.61
- Water temperature 7°C
- Capacity 12.7 kW
- Rated input 4.98 kW
- EER 2.55
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 185.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.62
- Water outlet at 55⁰C 3.41
- SEER
- Water outlet at 7⁰C 4.79
- Water outlet at 18⁰C 6.81
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9/3 kW/Ph
- MOP/MCA 14/11 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 65/51/43 dB(A)
- Indoor 44/25 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 112/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS16T/
HU160WT240T9 - Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 16.0 kW
- Rated input 3.56 kW
- COP 4.5
- Water temperature 55°C
- Capacity 16.0 kW
- Rated input 5.52 kW
- COP 2.85
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 14.2 kW
- Rated input 3.94 kW
- EER 3.61
- Water temperature 7°C
- Capacity 14.0 kW
- Rated input 5.71 kW
- EER 2.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 181.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 133.2
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.62
- Water outlet at 55⁰C 3.41
- SEER
- Water outlet at 7⁰C 4.58
- Water outlet at 18⁰C 6.63
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9/3 kW/Ph
- MOP/MCA 14/12 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 68/55/43 dB(A)
- Indoor 44/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 112/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
More
Zone Control
With the use of external thermostats you can set up to 8 different zones*, thus covering all the different thermal needs of the space and achieve maximum energy savings and comfort. The water circuit can be separated into 2 different zones. *For more than 2 zones, AT-TCK-6 installation is required
Weather Temperature Setting
By activating one of the 32 weather temperature settings the heat pump will automatically adjust the leaving water temperature according to the current outdoor ambient temperature providing ideal comfortable conditions with increased energy savings.
Modbus RTU
Connect up to 16 heat pumps with your building management system through Modbus RTU protocol to fully incorporate to your smart house/building and achieve complete control of the environment of your space.
Auto Restart
In case of a power failure, the heat pump will automatically restart according to the previous settings.
Media Library for Matrix Split Type Integrated Heat Pumps
User's & Wired Controller Manuals - Energy Labels - Technical Specifications - High Resolution Photos - Product Fiche
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …