Integrated Matrix Heat Pumps, a complete heating solution for every need!

  • Advanced design and easy installation
  • Complete solution for comfort and space saving
  • Ready to use system
  • Built-in indoor unit which upgrades your space
  • A+++* Energy Class with lower energy consumption**
  • Heating operation even at -25°C
  • Central control with touch wired controller for easy usage and a variety of functions

Contact us

*According to measurements conducted in accordance with European Regulation (EU) No 811/2013.

**According to measurements conducted by the National Technical University of Athens (NTUA)

Enjoy easy and flexible control with built-in Wi-Fi. Download the app from Google Play or the App Store and manage your appliance directly from your smartphone or tablet.

The advanced design of the outdoor unit, featuring a dedicated heating zone on the lower section and compressor, supports reliable operation even in demanding weather conditions, providing efficient heating for your space.

Reduce the heat pump noise levels even further by selecting between the two different levels of silent operation.

Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.

With All DC Inverter technology, the heat pumps operate smoothly and efficiently adapt to the needs of your space.

Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.

Inventor Heat Pumps can connect to a Smart Grid, adapting their operation to grid conditions. They can activate Domestic Hot Water (DHW) production when grid demand is lower and limit operation during periods of increased demand, contributing to more efficient energy management.

Protect your home's floor thanks to the underfloor drying function, which can gradually increase the underfloor heating temperature to avoid damage to the floor and for a smoother transition to heating mode. The Floor Drying Up function is an additional solution for the installer, as it helps to remove any residual moisture that may occur when installing new underfloor heating circuits, thus protecting the new installation and ensuring better and more efficient use of the heat pump.

Comfort, flexibility and efficient heating management with the ability to control two separate zones.

Adjust your heat pump’s operation while you are away with the Holiday/Away mode. Easily create the right operating profile to suit changes in your daily routine with the Holiday/Home option.

In case of a power failure, the heat pump will automatically restart according to the previous settings.

  • ATS04S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 4.25 kW
  • Rated input 0.82 kW
  • COP 5.20
  • Water temperature 55°C
  • Capacity 4.4 kW
  • Rated input 1.49 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 4.5 kW
  • Rated input 0.81 kW
  • EER 5.55
  • Water temperature 7°C
  • Capacity 4.7 kW
  • Rated input 1.36 kW
  • EER 3.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 191
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 129.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.85
  • Water outlet at 55⁰C 3.31
  • SEER
  • Water outlet at 7⁰C 4.98
  • Water outlet at 18⁰C 7.77
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/12 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 56/44/39 dB(A)
  • Indoor 38/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 58/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS04S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 4.25 kW
  • Rated input 0.82 kW
  • COP 5.20
  • Water temperature 55°C
  • Capacity 4.4 kW
  • Rated input 1.49 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 4.5 kW
  • Rated input 0.81 kW
  • EER 5.55
  • Water temperature 7°C
  • Capacity 4.7 kW
  • Rated input 1.36 kW
  • EER 3.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 191
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 129.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.85
  • Water outlet at 55⁰C 3.31
  • SEER
  • Water outlet at 7⁰C 4.98
  • Water outlet at 18⁰C 7.77
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/12 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 56/44/39 dB(A)
  • Indoor 38/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 58/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS06S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 6.2 kW
  • Rated input 1.24 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 6.0 kW
  • Rated input 2.03 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 6.55 kW
  • Rated input 1.34 kW
  • EER 4.9
  • Water temperature 7°C
  • Capacity 7.0 kW
  • Rated input 2.33 kW
  • EER 3.00
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 195
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 137.9
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.95
  • Water outlet at 55⁰C 3.52
  • SEER
  • Water outlet at 7⁰C 5.31
  • Water outlet at 18⁰C 8.25
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/14 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 58/45/40 dB(A)
  • Indoor 38/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 58/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS06S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 6.2 kW
  • Rated input 1.24 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 6.0 kW
  • Rated input 2.03 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 6.55 kW
  • Rated input 1.34 kW
  • EER 4.9
  • Water temperature 7°C
  • Capacity 7.0 kW
  • Rated input 2.33 kW
  • EER 3.00
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 195
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 137.9
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.95
  • Water outlet at 55⁰C 3.52
  • SEER
  • Water outlet at 7⁰C 5.31
  • Water outlet at 18⁰C 8.25
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/14 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 58/45/40 dB(A)
  • Indoor 38/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 58/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS08S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 8.3 kW
  • Rated input 1.6 kW
  • COP 5.2
  • Water temperature 55°C
  • Capacity 7.5 kW
  • Rated input 2.36 kW
  • COP 3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 8.4 kW
  • Rated input 1.66 kW
  • EER 5.05
  • Water temperature 7°C
  • Capacity 7.4 kW
  • Rated input 2.19 kW
  • EER 3.38
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 205.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 131.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.22
  • Water outlet at 55⁰C 3.36
  • SEER
  • Water outlet at 7⁰C 5.83
  • Water outlet at 18⁰C 8.95
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/16 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 59/46/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 75/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS08S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 8.3 kW
  • Rated input 1.6 kW
  • COP 5.2
  • Water temperature 55°C
  • Capacity 7.5 kW
  • Rated input 2.36 kW
  • COP 3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 8.4 kW
  • Rated input 1.66 kW
  • EER 5.05
  • Water temperature 7°C
  • Capacity 7.4 kW
  • Rated input 2.19 kW
  • EER 3.38
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 205.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 131.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.22
  • Water outlet at 55⁰C 3.36
  • SEER
  • Water outlet at 7⁰C 5.83
  • Water outlet at 18⁰C 8.95
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/16 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 59/46/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 75/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS10S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 10.0 kW
  • Rated input 2.0 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 9.5 kW
  • Rated input 3.06 kW
  • COP 3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 10.0 kW
  • Rated input 2.08 kW
  • EER 4.8
  • Water temperature 7°C
  • Capacity 8.2 kW
  • Rated input 2.48 kW
  • EER 3.3
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 204.8
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 136.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.2
  • Water outlet at 55⁰C 3.49
  • SEER
  • Water outlet at 7⁰C 5.96
  • Water outlet at 18⁰C 8.8
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/17 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 60/49/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 75/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS10S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 10.0 kW
  • Rated input 2.0 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 9.5 kW
  • Rated input 3.06 kW
  • COP 3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 10.0 kW
  • Rated input 2.08 kW
  • EER 4.8
  • Water temperature 7°C
  • Capacity 8.2 kW
  • Rated input 2.48 kW
  • EER 3.3
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 204.8
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 136.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.2
  • Water outlet at 55⁰C 3.49
  • SEER
  • Water outlet at 7⁰C 5.96
  • Water outlet at 18⁰C 8.8
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/17 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 60/49/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 75/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS12S/
    HU160WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.87 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.0 kW
  • Rated input 3.0 kW
  • EER 4.0
  • Water temperature 7°C
  • Capacity 11.6 kW
  • Rated input 4.22 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189.4
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.1
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.93
  • Water outlet at 18⁰C 7.14
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/25 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x25 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 64/50/43 dB(A)
  • Indoor 42/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 97/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS14S/
    HU160WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.09 kW
  • COP 4.70
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.60 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.5 kW
  • Rated input 3.74 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 12.7 kW
  • Rated input 4.98 kW
  • EER 2.55
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185.7
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.81
  • Water outlet at 18⁰C 6.86
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/26 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x32 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 65/51/43 dB(A)
  • Indoor 44/25 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 97/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS16S/
    HU160WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 16.0 kW
  • Rated input 3.56 kW
  • COP 4.50
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.52 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.2 kW
  • Rated input 3.94 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.71 kW
  • EER 2.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.7
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133.3
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.6
  • Water outlet at 18⁰C 6.67
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/27 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x32 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 68/54/43 dB(A)
  • Indoor 44/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 97/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS12T/
    HU160WT240T9
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.87 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.0 kW
  • Rated input 3.00 kW
  • EER 4.0
  • Water temperature 7°C
  • Capacity 11.6 kW
  • Rated input 4.22 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189.3
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.1
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.83
  • Water outlet at 18⁰C 7.0
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/10 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 4x16 (quadpolar fuse kinetic) No x Α
  • External unit fuses 4x16 (quadpolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 64/50/43 dB(A)
  • Indoor 42/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 112/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS14T/
    HU160WT240T9
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.09 kW
  • COP 4.7
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.6 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.5 kW
  • Rated input 3.74 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 12.7 kW
  • Rated input 4.98 kW
  • EER 2.55
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.79
  • Water outlet at 18⁰C 6.81
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/11 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 4x16 (quadpolar fuse kinetic) No x Α
  • External unit fuses 4x16 (quadpolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 65/51/43 dB(A)
  • Indoor 44/25 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 112/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS16T/
    HU160WT240T9
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 16.0 kW
  • Rated input 3.56 kW
  • COP 4.5
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.52 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.2 kW
  • Rated input 3.94 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.71 kW
  • EER 2.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133.2
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.58
  • Water outlet at 18⁰C 6.63
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/12 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 4x16 (quadpolar fuse kinetic) No x Α
  • External unit fuses 4x16 (quadpolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 68/55/43 dB(A)
  • Indoor 44/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 112/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C

Useful files of Matrix Split Integrated Type Heat Pumps

Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Databook

Contact us

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …

Thank you for your registration!