Features/ Technologies
Wi-Fi Standard
Through the smart Wi-Fi management, you get to create the environment you desire, from anywhere. Free download the Comfort Home app from Google Play or App Store and save energy operating your appliance through your smartphone or tablet.
Compressor and Chassis Heating Belt
The heat pump units are designed with pre-installed heating belts located on the chassis and the compressor to ensure their protected operation even at extreme weather conditions, a longer operation life, and provide high efficiency and stellar heating conditions quickly and effectively.
2 Stage Silent Mode
Reduce the heat pump noise levels even further by selecting between the two different levels of silent operation.
Disinfection Function 65~70⁰C
Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.
Fast Domestic Hot Water Function
You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.
All DC Inverter
With the inclusion of All DC Inverter technology, Inventor heat pumps operate at the ideal settings according to the constantly changing consumption needs, operating at the lowest possible noise levels while at the same time saving energy.
Backup Heating Source Control
Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.
Smart Grid Ready
Designed as environmental friendly, Inventor heat pumps can connect with a Smart City’s Smart Grid. Through their connection with the Smart Grid, the heat pumps can automatically alter their operation to activate the DHW production when there is excess energy available or to restrict their operation when the electricity grid is overtaxed, saving energy and helping protect the environment.
Underfloor drying operation
Protect your home's floor thanks to the underfloor drying function, which can gradually increase the underfloor heating temperature to avoid damage to the floor and for a smoother transition to heating mode. The Floor Drying Up function is an additional solution for the installer, as it helps to remove any residual moisture that may occur when installing new underfloor heating circuits, thus protecting the new installation and ensuring better and more efficient use of the heat pump.
Control 2 zones
Ensure energy savings, comfort and flexibility. The heat pumps have the possibility of controlling 2 heating zones, for example application with radiators and underfloor heating.
Holiday Mode
Reduce energy consumption while saving money even when away from home with the Holiday Away mode. You can additionally program the heat pump with different operation settings through the Holiday Home mode, to activate quick and easy when your home activity changes from your typical daily schedule.
Modbus RTU
Connect up to 16 heat pumps with your building management system through Modbus RTU protocol to fully incorporate to your smart house/building and achieve complete control of the environment of your space.
Auto Restart
In case of a power failure, the heat pump will automatically restart according to the previous settings.
Technical Specifications
- ATS04S/
HU100WT190S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 4.25 kW
- Rated input 0.82 kW
- COP 5.20
- Water temperature 55°C
- Capacity 4.4 kW
- Rated input 1.49 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 4.5 kW
- Rated input 0.81 kW
- EER 5.55
- Water temperature 7°C
- Capacity 4.7 kW
- Rated input 1.36 kW
- EER 3.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 191
- class A+++
- Water outlet at 55⁰C
- ηs (%) 129.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.85
- Water outlet at 55⁰C 3.31
- SEER
- Water outlet at 7⁰C 4.98
- Water outlet at 18⁰C 7.77
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/12 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 56/44/39 dB(A)
- Indoor 38/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 58/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS04S/
HU100WT240S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 4.25 kW
- Rated input 0.82 kW
- COP 5.20
- Water temperature 55°C
- Capacity 4.4 kW
- Rated input 1.49 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 4.5 kW
- Rated input 0.81 kW
- EER 5.55
- Water temperature 7°C
- Capacity 4.7 kW
- Rated input 1.36 kW
- EER 3.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 191
- class A+++
- Water outlet at 55⁰C
- ηs (%) 129.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.85
- Water outlet at 55⁰C 3.31
- SEER
- Water outlet at 7⁰C 4.98
- Water outlet at 18⁰C 7.77
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/12 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 56/44/39 dB(A)
- Indoor 38/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 58/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS06S/
HU100WT190S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 6.2 kW
- Rated input 1.24 kW
- COP 5.0
- Water temperature 55°C
- Capacity 6.0 kW
- Rated input 2.03 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 6.55 kW
- Rated input 1.34 kW
- EER 4.9
- Water temperature 7°C
- Capacity 7.0 kW
- Rated input 2.33 kW
- EER 3.00
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 195
- class A+++
- Water outlet at 55⁰C
- ηs (%) 137.9
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.95
- Water outlet at 55⁰C 3.52
- SEER
- Water outlet at 7⁰C 5.31
- Water outlet at 18⁰C 8.25
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/14 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 58/45/40 dB(A)
- Indoor 38/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 58/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS06S/
HU100WT240S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 6.2 kW
- Rated input 1.24 kW
- COP 5.0
- Water temperature 55°C
- Capacity 6.0 kW
- Rated input 2.03 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 6.55 kW
- Rated input 1.34 kW
- EER 4.9
- Water temperature 7°C
- Capacity 7.0 kW
- Rated input 2.33 kW
- EER 3.00
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 195
- class A+++
- Water outlet at 55⁰C
- ηs (%) 137.9
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.95
- Water outlet at 55⁰C 3.52
- SEER
- Water outlet at 7⁰C 5.31
- Water outlet at 18⁰C 8.25
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/14 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.50 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 58/45/40 dB(A)
- Indoor 38/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008x712x426 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 58/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS08S/
HU100WT190S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 8.3 kW
- Rated input 1.6 kW
- COP 5.2
- Water temperature 55°C
- Capacity 7.5 kW
- Rated input 2.36 kW
- COP 3.18
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 8.4 kW
- Rated input 1.66 kW
- EER 5.05
- Water temperature 7°C
- Capacity 7.4 kW
- Rated input 2.19 kW
- EER 3.38
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 205.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 131.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.22
- Water outlet at 55⁰C 3.36
- SEER
- Water outlet at 7⁰C 5.83
- Water outlet at 18⁰C 8.95
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/16 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 59/46/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 75/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS08S/
HU100WT240S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 8.3 kW
- Rated input 1.6 kW
- COP 5.2
- Water temperature 55°C
- Capacity 7.5 kW
- Rated input 2.36 kW
- COP 3.18
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 8.4 kW
- Rated input 1.66 kW
- EER 5.05
- Water temperature 7°C
- Capacity 7.4 kW
- Rated input 2.19 kW
- EER 3.38
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 205.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 131.5
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.22
- Water outlet at 55⁰C 3.36
- SEER
- Water outlet at 7⁰C 5.83
- Water outlet at 18⁰C 8.95
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/16 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 59/46/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 75/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS10S/
HU100WT190S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 10.0 kW
- Rated input 2.0 kW
- COP 5.0
- Water temperature 55°C
- Capacity 9.5 kW
- Rated input 3.06 kW
- COP 3.1
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 10.0 kW
- Rated input 2.08 kW
- EER 4.8
- Water temperature 7°C
- Capacity 8.2 kW
- Rated input 2.48 kW
- EER 3.3
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 204.8
- class A+++
- Water outlet at 55⁰C
- ηs (%) 136.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.2
- Water outlet at 55⁰C 3.49
- SEER
- Water outlet at 7⁰C 5.96
- Water outlet at 18⁰C 8.8
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/17 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 60/49/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.683x600 mm
- Net weight Outdoor/Indoor 75/140 kg
- Domestic Hot Water Tank
- Volume 190 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS10S/
HU100WT240S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 10.0 kW
- Rated input 2.0 kW
- COP 5.0
- Water temperature 55°C
- Capacity 9.5 kW
- Rated input 3.06 kW
- COP 3.1
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 10.0 kW
- Rated input 2.08 kW
- EER 4.8
- Water temperature 7°C
- Capacity 8.2 kW
- Rated input 2.48 kW
- EER 3.3
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 204.8
- class A+++
- Water outlet at 55⁰C
- ηs (%) 136.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.2
- Water outlet at 55⁰C 3.49
- SEER
- Water outlet at 7⁰C 5.96
- Water outlet at 18⁰C 8.8
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/17 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.65 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 60/49/41 dB(A)
- Indoor 40/22 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 75/157 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS12S/
HU160WT240S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 12.1 kW
- Rated input 2.44 kW
- COP 4.95
- Water temperature 55°C
- Capacity 11.9 kW
- Rated input 3.87 kW
- COP 3.05
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 12.0 kW
- Rated input 3.0 kW
- EER 4.0
- Water temperature 7°C
- Capacity 11.6 kW
- Rated input 4.22 kW
- EER 2.75
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 189.4
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.1
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.81
- Water outlet at 55⁰C 3.45
- SEER
- Water outlet at 7⁰C 4.93
- Water outlet at 18⁰C 7.14
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 30/25 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x6.0 / 2x25 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 64/50/43 dB(A)
- Indoor 42/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 97/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS14S/
HU160WT240S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 14.5 kW
- Rated input 3.09 kW
- COP 4.70
- Water temperature 55°C
- Capacity 13.8 kW
- Rated input 4.60 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 13.5 kW
- Rated input 3.74 kW
- EER 3.61
- Water temperature 7°C
- Capacity 12.7 kW
- Rated input 4.98 kW
- EER 2.55
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 185.7
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.81
- Water outlet at 55⁰C 3.45
- SEER
- Water outlet at 7⁰C 4.81
- Water outlet at 18⁰C 6.86
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 30/26 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 65/51/43 dB(A)
- Indoor 44/25 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 97/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS16S/
HU160WT240S3
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 16.0 kW
- Rated input 3.56 kW
- COP 4.50
- Water temperature 55°C
- Capacity 16.0 kW
- Rated input 5.52 kW
- COP 2.85
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 14.2 kW
- Rated input 3.94 kW
- EER 3.61
- Water temperature 7°C
- Capacity 14.0 kW
- Rated input 5.71 kW
- EER 2.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 181.7
- class A+++
- Water outlet at 55⁰C
- ηs (%) 133.3
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.72
- Water outlet at 55⁰C 3.47
- SEER
- Water outlet at 7⁰C 4.6
- Water outlet at 18⁰C 6.67
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 30/27 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 68/54/43 dB(A)
- Indoor 44/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 97/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS12T/
HU160WT240T9
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 12.1 kW
- Rated input 2.44 kW
- COP 4.95
- Water temperature 55°C
- Capacity 11.9 kW
- Rated input 3.87 kW
- COP 3.05
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 12.0 kW
- Rated input 3.00 kW
- EER 4.0
- Water temperature 7°C
- Capacity 11.6 kW
- Rated input 4.22 kW
- EER 2.75
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 189.3
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.1
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.72
- Water outlet at 55⁰C 3.47
- SEER
- Water outlet at 7⁰C 4.83
- Water outlet at 18⁰C 7.0
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9/3 kW/Ph
- MOP/MCA 14/10 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 64/50/43 dB(A)
- Indoor 42/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 112/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS14T/
HU160WT240T9
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 14.5 kW
- Rated input 3.09 kW
- COP 4.7
- Water temperature 55°C
- Capacity 13.8 kW
- Rated input 4.6 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 13.5 kW
- Rated input 3.74 kW
- EER 3.61
- Water temperature 7°C
- Capacity 12.7 kW
- Rated input 4.98 kW
- EER 2.55
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 185.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 135.6
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.62
- Water outlet at 55⁰C 3.41
- SEER
- Water outlet at 7⁰C 4.79
- Water outlet at 18⁰C 6.81
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9/3 kW/Ph
- MOP/MCA 14/11 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 65/51/43 dB(A)
- Indoor 44/25 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 112/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
- ATS16T/
HU160WT240T9
-
Heating
at Αmbient Temperature 7°C - Water temperature 35°C
- Capacity 16.0 kW
- Rated input 3.56 kW
- COP 4.5
- Water temperature 55°C
- Capacity 16.0 kW
- Rated input 5.52 kW
- COP 2.85
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 14.2 kW
- Rated input 3.94 kW
- EER 3.61
- Water temperature 7°C
- Capacity 14.0 kW
- Rated input 5.71 kW
- EER 2.45
-
Seasonal space heating
energy efficiency class
(Average) - Water outlet at 35⁰C
- ηs (%) 181.6
- class A+++
- Water outlet at 55⁰C
- ηs (%) 133.2
- class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.62
- Water outlet at 55⁰C 3.41
- SEER
- Water outlet at 7⁰C 4.58
- Water outlet at 18⁰C 6.63
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9/3 kW/Ph
- MOP/MCA 14/12 A
- Compressor
- Tipo Twin rotary Mitsubishi
- Refrigerant
-
Type / Charged volume
(up to 15m) R32/1.84 kg - Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inch
- Power Supply Wire Indoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire Outdoor 5x2.5 / 4x16 (quadpolar fuse kinetic) No x mm² / No x Α
- Power Supply Wire 3x1.0 shielded No x mm² / No x Α
- Sound (power/pressure/ pressure silent 2)
- Outdoor 68/55/43 dB(A)
- Indoor 44/24 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 600x1.943x600 mm
- Net weight Outdoor/Indoor 112/159 kg
- Domestic Hot Water Tank
- Volume 240 L
-
Max Water Temperature
(during Disinfection) 70 ⁰C - Max Water Pressure 10 bar
- Material Stainless Steel
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW (tank) 30~60 ⁰C
Useful files of Matrix Split Integrated Type Heat Pumps
Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Databook
Contact us
Find more
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …