Matrix Monoblock Type Heat Pumps for high efficiency, energy savings & ultimate comfort!

  • A+++ energy class for excellent performance and reduced functional cost
  • Specially designed units with up to 65°C delivery capability for ideal conditions even at low outdoor ambient temperatures
  • Central control of your appliances thanks to the multi-functional touch wired controller
  • Easy Wi-Fi management of your appliance
  • Reliable water pump that can lift up to 9m & higher efficiency with the Wilo or Grundfos brands
  • Maximum unit protection with the compressor and chassis heating belt

Save energy from the heating & cooling of your place and the immediate hot water production

Inventor monoblock type heat pumps are equipped with modular technology allowing to connect up to 6 units to the same water circuit to be operated from a single wired controller, while the unit settings can be achieved easy and faster due to the easy addressing technology.

Reduce the heat pump noise levels even further by selecting between the two different levels of silent operation.

Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.

With the inclusion of All DC Inverter technology, Inventor heat pumps operate at the ideal settings according to the constantly changing consumption needs, operating at the lowest possible noise levels while at the same time saving energy.

You can select the operation priority of the heat pump. The heat pump will prioritize DHW production or space heating & cooling according to your needs.

Designed as environmental friendly, Inventor heat pumps can connect with a Smart City’s Smart Grid. Through their connection with the Smart Grid, the heat pumps can automatically alter their operation to activate the DHW production when there is excess energy available or to restrict their operation when the electricity grid is overtaxed, saving energy and helping protect the environment.

Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.

With the use of external thermostats you can set up to 8 different zones*, thus covering all the different thermal needs of the space and achieve maximum energy savings and comfort. The water circuit can be separated into 2 different zones. *For more than 2 zones, AT-TCK-6 installation is required

Drastically reduce the installation time via the use of a built-in USB port, that allows you to copy and transfer the unit settings fast and easy across multiple units.

  • ATMH06S3
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 6.35 kW
  • Rated input 1.28 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 6.0 kW
  • Rated input 2.03 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 6.5 kW
  • Rated input 1.35 kW
  • EER 4.8
  • Water
  • Capacity 7.0 kW
  • Rated input 2.33 kW
  • EER 3.0
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 195
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 138
  • Energy Class A+++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.95
  • Water outlet at 55⁰C 3.52
  • SEER
  • Water outlet at 7⁰C 5.34
  • Water outlet at 18⁰C 8.21
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/14 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.4 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1'' inch
  • Power Supply Wire 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 58/47.5/40 dB(A)
  • Unit dimension (WxHxD) 1.295x792x429 mm
  • Net weight 103 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH08S3
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 8.4 kW
  • Rated input 1.63 kW
  • COP 5.15
  • Water temperature 55°C
  • Capacity 7.5 kW
  • Rated input 2.36 kW
  • COP 3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 8.3 kW
  • Rated input 1.64 kW
  • EER 5.05
  • Water temperature 7°C
  • Capacity 7.45 kW
  • Rated input 2.22 kW
  • EER 3.35
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 205
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 131
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.21
  • Water outlet at 55⁰C 3.36
  • SEER
  • Water outlet at 7⁰C 5.83
  • Water outlet at 18⁰C 8.95
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/16 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.4 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 59/48.5/41 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 133 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH10S3
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 10.0 kW
  • Rated input 2.02 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 9.5 kW
  • Rated input 3.06 kW
  • COP 3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 9.9 kW
  • Rated input 2.18 kW
  • EER 4.55
  • Water temperature 7°C
  • Capacity 8.2 kW
  • Rated input 2.52 kW
  • EER 3.25
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 204
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 136
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.19
  • Water outlet at 55⁰C 3.49
  • SEER
  • Water outlet at 7⁰C 5.98
  • Water outlet at 18⁰C 8.78
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/17 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.4 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 60/50.5/41 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 133 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH12S3
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.9 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.0 kW
  • Rated input 3.04 kW
  • EER 3.95
  • Water temperature 7°C
  • Capacity 11.5 kW
  • Rated input 4.18 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.89
  • Water outlet at 18⁰C 7.1
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/25 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x16.0 / 2x50 (bipolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/53/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 149 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH14S3
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.15 kW
  • COP 4.60
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.68 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.50 kW
  • Rated input 3.75 kW
  • EER 3.60
  • Water temperature 7°C
  • Capacity 12.4 kW
  • Rated input 4.96 kW
  • EER 2.50
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.86
  • Water outlet at 18⁰C 6.9
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/26 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x16.0 / 2x50 (bipolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/53.5/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 134 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH16S3
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 15.9 kW
  • Rated input 3.53 kW
  • COP 4.5
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.61 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.9 kW
  • Rated input 4.38 kW
  • EER 3.4
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.6 kW
  • EER 2.5
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.7
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133.3
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.69
  • Water outlet at 18⁰C 6.75
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/27 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x10.0 / 2x32 (bipolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 69/57.5/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 149 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH12T9
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.9 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.0 kW
  • Rated input 3.04 kW
  • EER 3.95
  • Water temperature 7°C
  • Capacity 11.5 kW
  • Rated input 4.18 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.86
  • Water outlet at 18⁰C 7.04
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/10 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x6.0 / 4x25 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/53.5/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 166 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH14T9
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.15 kW
  • COP 4.6
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.68 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.5 kW
  • Rated input 3.75 kW
  • EER 3.6
  • Water temperature 7°C
  • Capacity 12.4 kW
  • Rated input 4.96 kW
  • EER 2.5
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.83
  • Water outlet at 18⁰C 6.85
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/11 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x6.0 / 4x25 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/54/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 166 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATMH16T9
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 15.9 kW
  • Rated input 3.53 kW
  • COP 4.5
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.61 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.9 kW
  • Rated input 4.38 kW
  • EER 3.4
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.6 kW
  • EER 2.5
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.6
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.67
  • Water outlet at 18⁰C 6.71
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/12 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x6.0 / 4x25 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 69/58/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 166 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM08S
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 8.40 kW
  • Rated input 1.63 kW
  • COP 5.15
  • Water temperature 55°C
  • Capacity 7.50 kW
  • Rated input 2.36 kW
  • COP 3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 8.30 kW
  • Rated input 1.64 kW
  • EER 5.05
  • Water temperature 7°C
  • Capacity 7.45 kW
  • Rated input 2.22 kW
  • EER 3.35
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 205
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 131
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.21
  • Water outlet at 55⁰C 3.36
  • SEER
  • Water outlet at 7⁰C 5.83
  • Water outlet at 18⁰C 8.95
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 19/16 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.40 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x4.0 / 2x20 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 59/48.5/41 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 121 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM10S
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 10.0 kW
  • Rated input 2.02 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 9.50 kW
  • Rated input 3.06 kW
  • COP 3.10
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 9.90 kW
  • Rated input 2.18 kW
  • EER 4.55
  • Water temperature 7°C
  • Capacity 8.20 kW
  • Rated input 2.52 kW
  • EER 3.25
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 204
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 136
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.19
  • Water outlet at 55⁰C 3.49
  • SEER
  • Water outlet at 7⁰C 5.98
  • Water outlet at 18⁰C 8.78
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 19/17 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.40 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x4.0 / 2x20 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 60/50.5/41 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 121 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM12S
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.90 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.00 kW
  • Rated input 3.04 kW
  • EER 3.95
  • Water temperature 7°C
  • Capacity 11.5 kW
  • Rated input 4.18 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.89
  • Water outlet at 18⁰C 7.1
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 30/25 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x6.0 / 2x25 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/53/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 144 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM14S
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.15 kW
  • COP 4.60
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.68 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.50 kW
  • Rated input 3.75 kW
  • EER 3.60
  • Water temperature 7°C
  • Capacity 12.4 kW
  • Rated input 4.96 kW
  • EER 2.50
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.86
  • Water outlet at 18⁰C 6.9
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 30/26 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x10.0 / 2x32 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/53.5/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 129 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM16S
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 15.9 kW
  • Rated input 3.53 kW
  • COP 4.50
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.61 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.90 kW
  • Rated input 4.38 kW
  • EER 3.40
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.60 kW
  • EER 2.50
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.7
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133.3
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.69
  • Water outlet at 18⁰C 6.75
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 30/27 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 3x10.0 / 2x32 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 69/57.5/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 144 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM12T
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.90 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.00 kW
  • Rated input 3.04 kW
  • EER 3.95
  • Water temperature 7°C
  • Capacity 11.5 kW
  • Rated input 4.18 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.86
  • Water outlet at 18⁰C 7.04
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 14/10 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x2.5 / 4x20 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/53.5/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 160 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM14T
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.15 kW
  • COP 4.60
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.68 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.50 kW
  • Rated input 3.75 kW
  • EER 3.60
  • Water temperature 7°C
  • Capacity 12.4 kW
  • Rated input 4.96 kW
  • EER 2.50
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.83
  • Water outlet at 18⁰C 6.85
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 14/11 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x2.5 / 4x20 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 65/54/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 160 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM16T
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 15.9 kW
  • Rated input 3.53 kW
  • COP 4.50
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.61 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.90 kW
  • Rated input 4.38 kW
  • EER 3.40
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.60 kW
  • EER 2.50
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.6
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.67
  • Water outlet at 18⁰C 6.71
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 14/12 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.75 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x2.5 / 4x20 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 69/58/43 dB(A)
  • Unit dimension (WxHxD) 1.385x945x526 mm
  • Net weight 160 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW (tank) 10~60 ⁰C
  • ATM22T
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 22.0 kW
  • Rated input 5.0 kW
  • COP 4.4
  • Water temperature 55°C
  • Capacity 22.0 kW
  • Rated input 8.3 kW
  • COP 2.65
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 21.0 kW
  • Rated input 7.12 kW
  • EER 2.95
  • Water temperature 7°C
  • Capacity 23.0 kW
  • Rated input 5.0 kW
  • EER 4.6
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 178.1
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs (%) 125.8
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.53
  • Water outlet at 55⁰C 3.22
  • SEER
  • Water outlet at 7⁰C 4.7
  • Water outlet at 18⁰C 5.67
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 21/24.5 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/5.0 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x6 / 4x25 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 73/59.8/54 dB(A)
  • Unit dimension (WxHxD) 1.129x1.558x440 mm
  • Net weight 177 kg
  • Outdoor air temperature range
  • Cooling -5~46 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~60 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATM30T
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 30.1 kW
  • Rated input 7.7 kW
  • COP 3.91
  • Water temperature 55°C
  • Capacity 30.0 kW
  • Rated input 13.04 kW
  • COP 2.3
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 29.5 kW
  • Rated input 11.57 kW
  • EER 2.55
  • Water temperature 7°C
  • Capacity 31.0 kW
  • Rated input 7.75 kW
  • EER 4.0
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 164.5
  • Energy Class A++
  • Water outlet at 55⁰C
  • ηs (%) 122.5
  • Energy Class A+
  • SCOP (Average)
  • Water outlet at 35⁰C 4.19
  • Water outlet at 55⁰C 3.14
  • SEER
  • Water outlet at 7⁰C 4.49
  • Water outlet at 18⁰C 5.71
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater - kW/Ph
  • MOP/MCA 28/28.5 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/5.0 kg
  • Water side heat exchanger Plate type
  • Water side connection (inner dimension) R 1-1/4 inch
  • Power Supply Wire 5x6 / 4x25 (quadpolar fuse kinetic) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2) 77/63.5/57 dB(A)
  • Unit dimension (WxHxD) 1.129x1.558x440 mm
  • Net weight 177 kg
  • Outdoor air temperature range
  • Cooling -5~46 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~60 ⁰C
  • DHW (tank) 30~60 ⁰C

By activating one of the 32 weather temperature settings the heat pump will automatically adjust the leaving water temperature according to the current outdoor ambient temperature providing ideal comfortable conditions with increased energy savings.

Connect up to 16 heat pumps with your building management system through Modbus RTU protocol to fully incorporate to your smart house/building and achieve complete control of the environment of your space.

With the use of an electronic expansion valve, Inventor heat pumps achieve precise operation control and greater efficiency.

In case of a power failure, the heat pump will automatically restart according to the previous settings.

Media Library for Matrix Monoblock Type Heat Pumps

User's & Wired Controller Manuals - Energy Labels - Technical Specifications - High Resolution Photos - Product Fiche

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …