*According to measurements conducted in accordance with European Regulation (EU) No 811/2013.
**According to measurements conducted by the National Technical University of Athens (NTUA)
Features/ Technologies
Disinfection Function 65~70⁰C
Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.
Fast Domestic Hot Water Function
You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.
All DC Inverter
With All DC Inverter technology, the heat pumps operate smoothly and efficiently adapt to the needs of your space.
Backup Heating Source Control
Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.
Smart Grid Ready
Inventor Heat Pumps can connect to a Smart Grid, adapting their operation to grid conditions. They can activate Domestic Hot Water (DHW) production when grid demand is lower and limit operation during periods of increased demand, contributing to more efficient energy management.
Underfloor drying operation
Protect your home's floor thanks to the underfloor drying function, which can gradually increase the underfloor heating temperature to avoid damage to the floor and for a smoother transition to heating mode. The Floor Drying Up function is an additional solution for the installer, as it helps to remove any residual moisture that may occur when installing new underfloor heating circuits, thus protecting the new installation and ensuring better and more efficient use of the heat pump.
Control 2 zones
Comfort, flexibility and efficient heating management with the ability to control two separate zones.
Holiday Mode
Adjust your heat pump’s operation while you are away with the Holiday/Away mode. Easily create the right operating profile to suit changes in your daily routine with the Holiday/Home option.
Ευέλικτη Εγκατάσταση
Inventor Split Type units offer flexible installation thanks to their special design, allowing a height difference of up to 20 metres between the indoor and outdoor units and a total piping length of up to 30 metres.
DC Inverter Water Pump
Equipped with a reliable water pump, with lift up to 9m.
Built-in Hydraulic Components
The unit is fully equipped with all hydraulic parts offering ease of installation.
Auto Restart
In case of a power failure, the heat pump will automatically restart according to the previous settings.
Technical Specifications
- ATS04S/HU060S3
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 4.25 kW
- Rated input 0.82 kW
- COP 5.2
- Water temperature 55°C
- Capacity 4.4 kW
- Rated input 1.49 kW
- COP 2.95
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 4.5 kW
- Rated input 0.81 kW
- EER 5.55
- Water temperature 7°C
- Capacity 4.7 kW
- Rated input 1.36 kW
- EER 3.45
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 191 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 129 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.85
- Water outlet at 55⁰C 3.31
- SEER
- Water outlet at 7⁰C 4.99
- Water outlet at 18⁰C 7.77
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/12 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.5 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
- External unit fuses 2x20 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 56/44/39 dB(A)
- Indoor 38/28 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008×712×426 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 60/43 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW 30~60 tank
- ATS06S/HU060S3
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 6.2 kW
- Rated input 1.24 kW
- COP 5.0
- Water temperature 55°C
- Capacity 6.0 kW
- Rated input 2.0 kW
- COP 3.0
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 6.55 kW
- Rated input 1.34 kW
- EER 4.90
- Water temperature 7°C
- Capacity 7.0 kW
- Rated input 2.33 kW
- EER 3.00
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 195 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 138 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.95
- Water outlet at 55⁰C 3.52
- SEER
- Water outlet at 7⁰C 5.34
- Water outlet at 18⁰C 8.21
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 18/14 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.5 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 1/4 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
- External unit fuses 2x20 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 58/45/40 dB(A)
- Indoor 38/28 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.008×712×426 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 60/43 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~25 ⁰C
- Heating 25~65 ⁰C
- DHW 30~60 tank
- ATS08S/HU100S3
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 8.3 kW
- Rated input 1.6 kW
- COP 5.2
- Water temperature 55°C
- Capacity 7.5 kW
- Rated input 2.36 kW
- COP 3.18
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 8.4 kW
- Rated input 1.66 kW
- EER 5.05
- Water temperature 7°C
- Capacity 7.4 kW
- Rated input 2.19 kW
- EER 3.38
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 205 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 131 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.21
- Water outlet at 55⁰C 3.36
- SEER
- Water outlet at 7⁰C 5.83
- Water outlet at 18⁰C 8.95
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/16 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.65 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
- External unit fuses 2x20 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 59/46/41 dB(A)
- Indoor 42/30 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 78.5/43 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
- ATS10S/HU100S3
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 10.0 kW
- Rated input 2.0 kW
- COP 5.0
- Water temperature 55°C
- Capacity 9.5 kW
- Rated input 3.06 kW
- COP 3.1
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 10.0 kW
- Rated input 2.08 kW
- EER 4.8
- Water temperature 7°C
- Capacity 8.2 kW
- Rated input 2.48 kW
- EER 3.3
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 204 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 136 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 5.19
- Water outlet at 55⁰C 3.49
- SEER
- Water outlet at 7⁰C 5.98
- Water outlet at 18⁰C 8.78
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 19/17 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.65 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
- External unit fuses 2x20 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 60/49/41 dB(A)
- Indoor 42/30 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 78.5/43 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
- ATS12S/HU160S3
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 12.1 kW
- Rated input 2.44 kW
- COP 4.95
- Water temperature 55°C
- Capacity 12.0 kW
- Rated input 3.87 kW
- COP 3.1
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 12.0 kW
- Rated input 3.0 kW
- EER 4.0
- Water temperature 7°C
- Capacity 11.6 kW
- Rated input 4.22 kW
- EER 2.75
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 189 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 135 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.81
- Water outlet at 55⁰C 3.45
- SEER
- Water outlet at 7⁰C 4.89
- Water outlet at 18⁰C 7.1
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3/1 kW/Ph
- MOP/MCA 30/25 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.84 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
- External unit fuses 2x25 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 64/50/43 dB(A)
- Indoor 43/32 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 100/45 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
- ATS14S/HU160S3
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 14.5 kW
- Rated input 3.09 kW
- COP 4.7
- Water temperature 55°C
- Capacity 13.8 kW
- Rated input 4.60 kW
- COP 3.0
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 13.50 kW
- Rated input 3.75 kW
- EER 3.60
- Water temperature 7°C
- Capacity 12.7 kW
- Rated input 4.98 kW
- EER 2.55
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 185 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 135 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.72
- Water outlet at 55⁰C 3.47
- SEER
- Water outlet at 7⁰C 4.86
- Water outlet at 18⁰C 6.9
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3 / 1 kW/Ph
- MOP/MCA 30/26 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.84 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
- External unit fuses 2x32 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 65/51/43 dB(A)
- Indoor 43/32 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 96/39 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
- ATS16S/HU160S3
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 16.0 kW
- Rated input 3.56 kW
- COP 4.50
- Water temperature 55°C
- Capacity 16.0 kW
- Rated input 5.52 kW
- COP 2.90
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 14.90 kW
- Rated input 4.38 kW
- EER 3.40
- Water temperature 7°C
- Capacity 14.0 kW
- Rated input 5.71 kW
- EER 2.45
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 182 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 133 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.62
- Water outlet at 55⁰C 3.41
- SEER
- Water outlet at 7⁰C 4.69
- Water outlet at 18⁰C 6.75
- Power supply 220-240/50/1 V/Hz/Ph
- Auxiliary Electric Heater 3 / 1 kW/Ph
- MOP/MCA 30/27 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.84 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
- External unit fuses 2x32 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 68/54/43 dB(A)
- Indoor 43/32 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 96/39 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
- ATS12T/HU160T9
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 12.1 kW
- Rated input 2.44 kW
- COP 4.95
- Water temperature 55°C
- Capacity 12.0 kW
- Rated input 3.87 kW
- COP 3.10
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 12.00 kW
- Rated input 3.00 kW
- EER 4.00
- Water temperature 7°C
- Capacity 11.6 kW
- Rated input 4.22 kW
- EER 2.75
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 189 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 135 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.81
- Water outlet at 55⁰C 3.45
- SEER
- Water outlet at 7⁰C 4.86
- Water outlet at 18⁰C 7.04
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9 / 3 kW/Ph
- MOP/MCA 14/10 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.84 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 4x20 (bipolar fuse kinetic) No x Α
- External unit fuses 4x20 (bipolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 64/50/43 dB(A)
- Indoor 43/32 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 112/45 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
- ATS14T/HU160T9
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 14.5 kW
- Rated input 3.09 kW
- COP 4.7
- Water temperature 55°C
- Capacity 13.8 kW
- Rated input 4.6 kW
- COP 3.0
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 13.5 kW
- Rated input 3.75 kW
- EER 3.6
- Water temperature 7°C
- Capacity 12.7 kW
- Rated input 4.98 kW
- EER 2.55
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 185 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 135 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.72
- Water outlet at 55⁰C 3.47
- SEER
- Water outlet at 7⁰C 4.83
- Water outlet at 18⁰C 6.85
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9 / 3 kW/Ph
- MOP/MCA 14/11 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.84 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 4x20 (bipolar fuse kinetic) No x Α
- External unit fuses 4x20 (quadpolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 65/51/43 dB(A)
- Indoor 43/32 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 116/45 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
- ATS16T/HU160T9
-
Heating
at Αmbient Temperature 7°C Average - Water temperature 35°C
- Capacity 16.0 kW
- Rated input 3.56 kW
- COP 4.5
- Water temperature 55°C
- Capacity 16.0 kW
- Rated input 5.52 kW
- COP 2.9
-
Cooling
at Ambient Temperature 35°C - Water temperature 18°C
- Capacity 14.9 kW
- Rated input 4.38 kW
- EER 3.4
- Water temperature 7°C
- Capacity 14.0 kW
- Rated input 5.71 kW
- EER 2.45
-
Seasonal space heating
energy efficiency class Average - Water outlet at 35⁰C
- ηs 182 %
- Energy Class A+++
- Water outlet at 55⁰C
- ηs 133 %
- Energy Class A++
- SCOP (Average)
- Water outlet at 35⁰C 4.62
- Water outlet at 55⁰C 3.41
- SEER
- Water outlet at 7⁰C 4.67
- Water outlet at 18⁰C 6.71
- Power supply 380-415/50/3 V/Hz/Ph
- Auxiliary Electric Heater 9 / 3 kW/Ph
- MOP/MCA 14/12 A
- Compressor
- Type Twin rotary Mitsubishi
- Refrigerant
- Type / Charged volume R32/1.84 up to 15m
- Water side heat exchanger Plate type
- Pipe size
- Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
- Indoor Unit Fuses 4x20 (bipolar fuse kinetic) No x Α
- External unit fuses 4x20 (quadpolar fuse kinetic) No x Α
- Signal Wires 3x1.0 shielded No x mm² / No x Α
- Sound (Power/Pressure/ Pressure silent 2)
- Outdoor 68/55/43 dB(A)
- Indoor 43/32 dB(A)
- Unit dimension (WxHxD)
- Outdoor 1.118x865x523 mm
- Indoor 420x790x270 mm
- Net weight ODU/IDU 116/45 kg
- Outdoor air temperature range
- Cooling -5~43 ⁰C
- Heating -25~35 ⁰C
- DHW -25~43 ⁰C
- Water outlet temperature range
- Cooling 5~30 ⁰C
- Heating 12~65 ⁰C
- DHW 10~60 tank
Useful files of Matrix Split Type Heat Pumps
Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Databook
Contact us
Find more
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …