V7i Ducted Air Conditioner Series. The Flexible Air Conditioning Solution for Every Commercial Space!

  • Static pressure and airflow adjustment
  • Ultra-slim design for easy installation
  • Horizontal or vertical installation for ultimate flexibility
  • Efficient operation with single-fan design*
  • Remote control via Wi-Fi Ready

*Available on the 50.000 and 60.000 BTU models.

Contact us

Eurovent"

The drain pump can lift the condensing water up to 750mm, serving every kind of installation. Refers to chest installations.

Take advantage of the Weekly Planner and adjust according to your needs, the air conditioner’s operating period, ensuring maximum energy and money savings. The new advanced wired controller, shows up the error codes and additionally enables you to activate the room temperature sensor via the wired controller instead of the air conditioner.

The golden anti-corrosion coating of the outdoor unit’s heat exchanger provides enhanced protection against corrosion, helping to maintain the air conditioner over time. It is an ideal choice for areas with high humidity or exposure to factors that promote corrosion, such as islands and coastal regions.

Fresh air duct connection capability for improved air quality.

The centralized multi-functional device can control up to 64 indoor units within a maximum connection length of 1200m. Control your air conditioner, set the temperature you want and select the mode you desire. Ideal for hotel & business units. *Requires separate purchase of connection kit

Choose between the bottom or the rear side for the air intake. It can fit all needs of the installations. Flexible air intake from the back or the bottom part of the unit.

The plethora of options provided by the ON/OFF contact gives you the flexibility you need to manage your air conditioners, saving time. Install Door Switches or remote switches to turn units on or off easily and instantly.

A smart sensor is mounted on the remote control. When the Follow Me function is activated, the unit adjusts the temperature of the room where the wireless controller is located, offering ideal conditions where you want them.

Hotel Menu is a set of features and settings, specially designed for small and large hotel businesses. It contributes to the easy setup and efficient operation of air conditioners.

Complete your building management system by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem including air conditioning, ventilation, lighting and security systems, ensuring full alignment with your building's needs. Enjoy the immediate, easy and efficient management of all these systems through a central system, thus improving performance and comfort in your building. *Separate connection kit purchase required

Take complete control of your air conditioner and keep it running properly at all times thanks to the ability to connect a remote fault indicator.

ECO Mode automatically sets the air conditioner's temperature to 24°C and adjusts the fan to Auto mode during cooling. This helps further reduce operating costs while offering a more environmentally friendly way to maintain an ideal indoor climate.

With the GEAR function, you can limit the maximum efficiency of the unit, choosing between two operating levels, at 75% or 50% of maximum efficiency. Thus, you adapt the operation of the air conditioner to the needs of the space, helping to better control energy consumption.

The iClean function ensures the best air quality in your space, removing accumulated dust, mold and bacteria from inside the unit.

Set the device to automatically turn on/off within 24 hours.

Enjoy excellent temperature conditions and tranquil atmosphere. The advanced design of the unit, featuring larger gaps between air ducts and an improved fan tilt, facilitates airflow and ensures quiet, efficient performance. Additionally, Silent Mode further reduces noise levels, allowing you to enjoy a perfect atmosphere undisturbed.

With sleep mode, the air conditioner adjusts the room temperature for ideal conditions during the night or during hours that require absolute silence.

With Turbo Mode, the fastest cooling of the room is achieved.

Enjoy the flexibility of the Delay feature by postponing the weekly scheduling mode by up to 3 hours. Change your device settings for a specific day without changing your weekly scheduling settings.

Ensure the operation of your device in cooling or heating without interventions. With the lockable feature, the air conditioner's function cannot be changed, avoiding incorrect settings. Ideal for workplaces or hotel rooms.

Turn off the ability to use the wireless controller to adjust your air conditioner to ensure central control of the device from a single point. Suitable for business premises and hotels.

The temperature perceived by the sensor of the indoor unit may differ from the actual temperature of our space, due to the installation position of the unit at a high height. With this function we minimize the difference and achieve the best conditions in the space.

The sensor of the indoor element controls the internal fan and prevents cold air from entering the room when starting in heating mode.

The air conditioner's sophisticated control design provides effective and efficient cooling operation in areas where special conditions are required, even at -15°C.

With the special design of the air conditioner, efficient heating is achieved even when extremely low temperatures prevail. Enjoy an ideal atmosphere even at -15°C.

In the event of unusual behavior, the unit will automatically shut down to protect the system. After a while, a protection code will appear on the screen for immediate repair.

In the event of a power failure, the air conditioning unit will automatically restart according to the previous settings.

The indoor unit will display an error code "EC" and stop automatically as soon as a coolant leak is diagnosed to protect the compressor from overheating.

Enjoy a quieter and more comfortable environment by turning off the sound of the keys and the air conditioner display.

Turn on lock mode to prevent children from changing settings or using them.

The fans of the indoor and outdoor unit, as well as the compressor, feature DC Inverter technology, allowing for smooth and efficient adjustment of the air conditioner's operation to suit the needs of the space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

  • V7iDI-12WiFiR / U7RS-12
  • Cooling Capacity 12.000 (2.800-13.334) Btu / h
  • Cooling Capacity 3.52 (0.53-3.91) kWatt
  • Heating Capacity 13.000 (3.400-15.241) Btu / h
  • Heating Capacity 3.81 (1.00-4.47) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A++
  • SEER 6.5
  • Heating Middle Zone
  • Pdesign 2.6 kW
  • Energy Class A+
  • SCOP 4.1
  • Heating Warm Zone
  • Pdesign 3.4 kW
  • Energy Class A+++
  • SCOP 5.1
  • Voltage/Frequency/Phase 220-240/50/1 V / Hz / Ph
  • Current Input - Cooling 4.77 (1.3-6.47) Α
  • Current Input - Heating 5.69 (1.4-6.29) Α
  • Power Input - Cooling 1.16 (0.15-1.465) kW
  • Power Input - Heating 1.28 (0.30-1.423) kW
  • Air Flow Volume (High/Medium/Low) 660/570/470 m³ / h
  • Maximum Condensate Lift 750 mm
  • Outdoor Static Pressure 0-100 Pa
  • Noise Level - Indoor unit
    (Low/Medium/High)
    23/29/30.5/34.5 db(A)
  • Στάθμη Θορύβου Εξωτερική Noise Level - Outdoor unit 55 db(A)
  • Sound Power Level - Indoor/Outdoor Unit 58/62 db(A)
  • Fuses 1x10 Α
  • Signal Wires 4x1.5 No x mm²
  • Supply Cables 3x1.5 Noxmm²
  • Dimensions - Indoor Unit
    (WxDxH)
    700x450x200 mm
  • Dimensions - Outdoor Unit
    (WxDxH)
    765x303x555 mm
  • Net Weight - Indoor/Outdoor Unit 17.8/26.6 kg
  • Liquid Line |Gas Line 1/4" | 3/8"
  • Refrigerant/Charge R32/710 g
  • Refrigerant Volume per Additional Meter of Pipe 12 g
  • Operation Temperature Range -
    Cooling/Heating
    -15~50 / -20~24 °C
  • V7iDI-24WiFiR / U7iRS-24
  • Cooling Capacity 24.200 (11.000-27.000) Btu / h
  • Cooling Capacity 7.09 (3.23-7.92) kWatt
  • Heating Capacity 25.931 (9.500-29.200) Btu / h
  • Heating Capacity 7.6 (2.79-8.56) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign 7.1 kW
  • Energy Class A++
  • SEER 6.6
  • Heating Middle Zone
  • Pdesign 5.6 kW
  • Energy Class A+
  • SCOP 4.2
  • Heating Warm Zone
  • Pdesign 6.5 kW
  • Energy Class A+++
  • SCOP 5.4
  • Voltage/Frequency/Phase 220-240/50/1 V / Hz / Ph
  • Current Input - Cooling 10.0 (4.2-12.6) Α
  • Current Input - Heating 9.0 (3.8-11.0) Α
  • Power Input - Cooling 2.28 (0.75-2.86) kW
  • Power Input - Heating 2.00 (0.64-2.50) kW
  • Air Flow Volume (High/Medium/Low) 1.200/1.000/700 m³ / h
  • Maximum Condensate Lift 750 mm
  • Outdoor Static Pressure 0-160 Pa
  • Noise Level - Indoor unit
    (Low/Medium/High)
    27/37/40/42 db(A)
  • Στάθμη Θορύβου Εξωτερική Noise Level - Outdoor unit 56 db(A)
  • Sound Power Level - Indoor/Outdoor Unit 62/68 db(A)
  • Fuses 1x16 Α
  • Signal Wires 4x1.5 No x mm²
  • Supply Cables 3x2.5 Noxmm²
  • Dimensions - Indoor Unit
    (WxDxH)
    1.100x774x249 mm
  • Dimensions - Outdoor Unit
    (WxDxH)
    890x342x673 mm
  • Net Weight - Indoor/Outdoor Unit 32.3/43.9 kg
  • Liquid Line |Gas Line 3/8" | 5/8"
  • Refrigerant/Charge R32/1.500 g
  • Refrigerant Volume per Additional Meter of Pipe 24 g
  • Operation Temperature Range -
    Cooling/Heating
    -15~50 / -20~24 °C
  • V7iDI-36WiFiR / U7RS-36
  • Cooling Capacity 36.000 (9.400-40.000) Btu / h
  • Cooling Capacity 10.55 (2.75-11.73) kWatt
  • Heating Capacity 40.000 (9.500-43.000) Btu / h
  • Heating Capacity 11.72 (2.78-12.61) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign 10.5 kW
  • Energy Class A++
  • SEER 6.3
  • Heating Middle Zone
  • Pdesign 8.4 kW
  • Energy Class A+
  • SCOP 4.1
  • Heating Warm Zone
  • Pdesign 10 kW
  • Energy Class A+++
  • SCOP 5.1
  • Voltage/Frequency/Phase 220-240/50/1 V / Hz / Ph
  • Current Input - Cooling 17.5 (4.2-19) Α
  • Current Input - Heating 14.5 (3.5-17.5) Α
  • Power Input - Cooling 3.95 (0.90-4.30) kW
  • Power Input - Heating 3.25 (0.80-3.95) kW
  • Air Flow Volume (High/Medium/Low) 1.700/1.400/1.100 m³ / h
  • Maximum Condensate Lift 750 mm
  • Outdoor Static Pressure 0-160 Pa
  • Noise Level - Indoor unit
    (Low/Medium/High)
    42/46/48/49.5 db(A)
  • Στάθμη Θορύβου Εξωτερική Noise Level - Outdoor unit 62 db(A)
  • Sound Power Level - Indoor/Outdoor Unit 61/70 db(A)
  • Fuses 1x25 Α
  • Signal Wires 4x1.5 No x mm²
  • Supply Cables 3x4.0 Noxmm²
  • Dimensions - Indoor Unit
    (WxDxH)
    1.360x774x249 mm
  • Dimensions - Outdoor Unit
    (WxDxH)
    946x410x810 mm
  • Net Weight - Indoor/Outdoor Unit 40.5/66.9 kg
  • Liquid Line |Gas Line 3/8" | 5/8"
  • Refrigerant/Charge R32/2.400 g
  • Refrigerant Volume per Additional Meter of Pipe 24 g
  • Operation Temperature Range -
    Cooling/Heating
    -15~50 / -20~24 °C
  • V7iDI-50WiFiR / U7iRT-50
  • Cooling Capacity 48.000 (12.000-54.000) Btu / h
  • Cooling Capacity 14.07 (3.52-15.83) kWatt
  • Heating Capacity 55.000 (14.000-60.000) Btu / h
  • Heating Capacity 16.12 (4.11-17.59) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign 14.0 kW
  • Energy Class A+
  • SEER 5.8
  • Heating Middle Zone
  • Pdesign 11.5 kW
  • Energy Class A+
  • SCOP 4.0
  • Heating Warm Zone
  • Pdesign 11.2 kW
  • Energy Class A++
  • SCOP 5.0
  • Voltage/Frequency/Phase 380-415/50/3 V / Hz / Ph
  • Current Input - Cooling 7.0 (1.8-10.5) Α
  • Current Input - Heating 8.0 (2.0-9.0) Α
  • Power Input - Cooling 4.50 (0.81-6.45) kW
  • Power Input - Heating 4.60 (0.95-5.80) kW
  • Air Flow Volume (High/Medium/Low) 2.000/1.700/1.300 m³ / h
  • Maximum Condensate Lift 750 mm
  • Outdoor Static Pressure 0-160 Pa
  • Noise Level - Indoor unit
    (Low/Medium/High)
    42/47/49/50 db(A)
  • Στάθμη Θορύβου Εξωτερική Noise Level - Outdoor unit 65 db(A)
  • Sound Power Level - Indoor/Outdoor Unit 66/74 db(A)
  • Fuses 3x16 Α
  • Signal Wires 4x1.5 No x mm²
  • Supply Cables 5x2.5 Noxmm²
  • Dimensions - Indoor Unit
    (WxDxH)
    1.200x874x300 mm
  • Dimensions - Outdoor Unit
    (WxDxH)
    952x415x1.333 mm
  • Net Weight - Indoor/Outdoor Unit 47.6/103.7 kg
  • Liquid Line |Gas Line 3/8" | 5/8"
  • Refrigerant/Charge R32/2.900 g
  • Refrigerant Volume per Additional Meter of Pipe 24 g
  • Operation Temperature Range -
    Cooling/Heating
    -15~50 / -20~24 °C
  • V7iDI-60WiFiR / U7iRT-60
  • Cooling Capacity 52.000 (14.000-59.000) Btu / h
  • Cooling Capacity 15.24 (4.10-17.29) kWatt
  • Heating Capacity 62.000 (15.000-70.000) Btu / h
  • Heating Capacity 18.18 (4.40-20.52) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign 15.3 kW
  • Energy Class A++
  • SEER 6.1
  • Heating Middle Zone
  • Pdesign 12.5 kW
  • Energy Class A+
  • SCOP 4.0
  • Heating Warm Zone
  • Pdesign 12.8 kW
  • Energy Class A+++
  • SCOP 5.1
  • Voltage/Frequency/Phase 380-415/50/3 V / Hz / Ph
  • Current Input - Cooling 8.1 (3.1-11.5) Α
  • Current Input - Heating 8.0 (2.0-11.5) Α
  • Power Input - Cooling 5.25 (1.03-6.65) kW
  • Power Input - Heating 5.15 (0.95-6.60) kW
  • Air Flow Volume (High/Medium/Low) 2.200/1.900/1.500 m³ / h
  • Maximum Condensate Lift 750 mm
  • Outdoor Static Pressure 0-160 Pa
  • Noise Level - Indoor unit
    (Low/Medium/High)
    43/47/49/52.5 db(A)
  • Στάθμη Θορύβου Εξωτερική Noise Level - Outdoor unit 66 db(A)
  • Sound Power Level - Indoor/Outdoor Unit 66/74 db(A)
  • Fuses 3x16 Α
  • Signal Wires 4x1.5 No x mm²
  • Supply Cables 5x2.5 Noxmm²
  • Dimensions - Indoor Unit
    (WxDxH)
    1.200x874x300 mm
  • Dimensions - Outdoor Unit
    (WxDxH)
    952x415x1.333 mm
  • Net Weight - Indoor/Outdoor Unit 47.4/107.0 kg
  • Liquid Line |Gas Line 3/8" | 5/8"
  • Refrigerant/Charge R32/3.000 g
  • Refrigerant Volume per Additional Meter of Pipe 24 g
  • Operation Temperature Range -
    Cooling/Heating
    -15~50 / -20~24 °C

Useful files of ducted V7i series

Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Technical Specifications & Features

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …

Thank you for your registration!