Features/ Technologies
Hotel Menu
Hotel Menu is a set of features and settings, specially designed for small and large hotel businesses. It contributes to the easy setup and efficient operation of air conditioners.
A+++ Energy Class
Enjoy ideal conditions in your space with high energy efficiency and low consumption. With energy class A+++* in heating (Hot Zone), with SCOP from 5.1 to 5.4. *Valid for models 12,000, 24,000, 36,000 and 42,000btu, based on the current table of Regulation (EU) 626/2011.
Golden Fin
The golden anti-corrosion coating of the outdoor unit’s heat exchanger provides enhanced protection against corrosion, helping to maintain the air conditioner over time. It is an ideal choice for areas with high humidity or exposure to factors that promote corrosion, such as islands and coastal regions.
Central Control Management (Optional)
The centralized multi-functional device can control up to 64 indoor units within a maximum connection length of 1200m. Control your air conditioner, set the temperature you want and select the mode you desire. Ideal for hotel & business units. *Refers to the units of 24.000~60.000btu/h
Remote On/Off
The plethora of options provided by the ON/OFF contact gives you the flexibility you need to manage your air conditioners, saving time. Install Door Switches or remote switches to turn units on or off easily and instantly.
Follow Me
A smart sensor is mounted on the remote control. When the Follow Me function is activated, the unit adjusts the temperature of the room where the wireless controller is located, offering ideal conditions where you want them.
360° Air Outlet
Enjoy unique comfort in every part of the room. The air comes out from 8 instead of 4 outlets and is efficiently transferred to every corner of the room.
BMS Connectivity (Optional)
Complete your building management system by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem including air conditioning, ventilation, lighting and security systems, ensuring full alignment with your building's needs. Enjoy the immediate, easy and efficient management of all these systems through a central system, thus improving performance and comfort in your building. *Separate connection kit purchase required
Weekly Planner Controller (Optional)
Take advantage of the Weekly Scheduling feature and adjust the air conditioner's operating time according to your needs. The advanced wired controller displays fault codes and also provides the ability to activate a room temperature sensor on the controller instead of on the air conditioning unit.
Error Alarm Port
Take complete control of your air conditioner and keep it running properly at all times thanks to the ability to connect a remote fault indicator.
ECO mode
ECO Mode automatically sets the air conditioner's temperature to 24°C and adjusts the fan to Auto mode during cooling. This helps further reduce operating costs while offering a more environmentally friendly way to maintain an ideal indoor climate.
GEAR Function
With the GEAR function, you can limit the maximum efficiency of the unit, choosing between two operating levels, at 75% or 50% of maximum efficiency. Thus, you adapt the operation of the air conditioner to the needs of the space, helping to better control energy consumption.
iClean Mode
The iClean function ensures the best air quality in your space, removing accumulated dust, mold and bacteria from inside the unit.
24-hour Timer
Set the device to automatically turn on/off within 24 hours.
Quiet Operation
Enjoy excellent temperature conditions and tranquil atmosphere. The advanced design of the unit, featuring larger gaps between air ducts and an improved fan tilt, facilitates airflow and ensures quiet, efficient performance. Additionally, Silent Mode further reduces noise levels, allowing you to enjoy a perfect atmosphere undisturbed.
Sleep Mode
With sleep mode, the air conditioner adjusts the room temperature for ideal conditions during the night or during hours that require absolute silence.
Turbo Mode
With Turbo Mode, the fastest cooling of the room is achieved.
Weekly Program Delay (Optional with the Weekly Planner Controller)
Enjoy the flexibility of the Delay feature by postponing the weekly scheduling mode by up to 3 hours. Change your device settings for a specific day without changing your weekly scheduling settings.
Operation Mode Lock (Optional with the Weekly Planner Controller)
Ensure the operation of your device in cooling or heating without interventions. With the lockable feature, the air conditioner's function cannot be changed, avoiding incorrect settings. Ideal for workplaces or hotel rooms.
Remote Controller Commands Deactivation (Optional with the Weekly Planner Controller)
Turn off the ability to use the wireless controller to adjust your air conditioner to ensure central control of the device from a single point. Suitable for business premises and hotels.
Temperature Offset Function
The temperature perceived by the sensor of the indoor unit may differ from the actual temperature of our space, due to the installation position of the unit at a high height. With this function we minimize the difference and achieve the best conditions in the space.
Anti-Cold Air Function
The sensor of the indoor element controls the internal fan and prevents cold air from entering the room when starting in heating mode.
Low Ambient Cooling
The air conditioner's sophisticated control design provides effective and efficient cooling operation in areas where special conditions are required, even at -15°C.
Excellent Heating Performance Under -15°C
With the special design of the air conditioner, efficient heating is achieved even when extremely low temperatures prevail. Enjoy an ideal atmosphere even at -15°C.
Auto Error Diagnosis
In the event of unusual behavior, the unit will automatically shut down to protect the system. After a while, a protection code will appear on the screen for immediate repair.
Auto Restart
In the event of a power failure, the air conditioning unit will automatically restart according to the previous settings.
Refrigerant Leakage Detect
The indoor unit will display an error code "EC" and stop automatically as soon as a coolant leak is diagnosed to protect the compressor from overheating.
Mute Mode
Enjoy a quieter and more comfortable environment by turning off the sound of the keys and the air conditioner display.
Lock
Turn on lock mode to prevent children from changing settings or using them.
All DC Inverter
The fans of the indoor and outdoor unit, as well as the compressor, feature DC Inverter technology, allowing for smooth and efficient adjustment of the air conditioner's operation to suit the needs of the space.
R32 ECO Refrigerant
The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.
Technical Specifications
- V7iCRI-12WiFiR / U7RS-12
- Cooling Capacity 12.000 (2.900-14.200) Btu / h
- Cooling Capacity 3.52 (0.85-4.16) kWatt
- Heating Capacity 13.000 (1.600-14.800) Btu / h
- Heating Capacity 3.81 (0.47-4.34) kWatt
- Seasonal Efficiency (In accordance to EN14825)
- Cooling
- Pdesign 3.5 kW
- Energy Class A++
- SEER 6.8
- Middle Zone Heating
- Pdesign 2.7 kW
- Energy Class A+
- SCOP 4.1
- Warm Zone Heating
- Pdesign 3.3 kW
- Energy Class A+++
- SCOP 5.1
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 4.5 (1.3-6.4) Α
- Current Input Heating 4.5 (1.1-6.2) Α
- Power Input Cooling 1.01 (0.16-1.45) kW
- Power Input Heating 1.02 (0.125-1.39) kW
- Air Flow Volume (High / Medium / Low) 620/520/330 m³ / h
- Maximum Condensate Lift 750 mm
- Noise Level Indoor unit (Low / Medium / High) 25.5/33/36/41 db(A)
- Noise Level Outdoor unit 53.6 db(A)
-
Sound Power
Indoor Unit /
Outdoor Unit 57/62 db(A) - Fuses 1x10 Α
- Command Cables 4x1.5 No x mm²
- Power Cables 3 x 1.5 No x mm²
- Dimensions WxDxH Panel 620x620x50 mm
- Dimensions WxDxH Indoor unit 570x570x245 mm
- Dimensions WxDxH Outdoor unit 765x303x555 mm
- Net Weight Panel / Indoor / Outdoor 2.7/16.1/26.6 kg
- Liquid line - Gas line 1/4" | 3/8"
- Maximum Distance - Horizontal 25
- Maximum Distance - Vertical 10
- Refrigerant / Charge R32/710 g
- Outdoor Operation Temperature Range Cooling / Heating -15~50 / -20~24 °C
- Indoor Panel Model CPi01
- V7CRI-18WiFiR / U7RS-18
- Cooling Capacity 18.000 (9.900-19.064) Btu / h
- Cooling Capacity 5.28 (2.90-5.59) kWatt
- Heating Capacity 19.000 (8.100-20.800) Btu / h
- Heating Capacity 5.57 (2.37-6.10) kWatt
- Seasonal Efficiency (In accordance to EN14825)
- Cooling
- Pdesign 5.3 kW
- Energy Class A++
- SEER 6.3
- Middle Zone Heating
- Pdesign 4.2 kW
- Energy Class A+
- SCOP 4.0
- Warm Zone Heating
- Pdesign 5.4 kW
- Energy Class A++
- SCOP 4.8
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 7.20 (3.20-9.20) Α
- Current Input Heating 6.80 (3.10-8.50) Α
- Power Input Cooling 1.63 (0.72-2.09) kW
- Power Input Heating 1.54 (0.70-1.93) kW
- Air Flow Volume (High / Medium / Low) 720/620/500 m³ / h
- Maximum Condensate Lift 750 mm
- Noise Level Indoor unit (Low / Medium / High) 29/35.5/39.5/43 db(A)
- Noise Level Outdoor unit 56 db(A)
-
Sound Power
Indoor Unit /
Outdoor Unit 59/65 db(A) - Fuses 1x16 Α
- Command Cables 4 x 1.5 No x mm²
- Power Cables 3 x 1.5 No x mm²
- Dimensions WxDxH Panel 647x647x50 mm
- Dimensions WxDxH Indoor unit 570x570x260 mm
- Dimensions WxDxH Outdoor unit 805x330x554 mm
- Net Weight Panel / Indoor / Outdoor 2.5/16.0/32.5 kg
- Liquid line - Gas line 1/4" | 1/2"
- Maximum Distance - Horizontal 30
- Maximum Distance - Vertical 20
- Refrigerant / Charge R32/1.150 g
- Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
- Indoor Panel Model CP01
- V7CI-24WiFiR / U7iRS-24
- Cooling Capacity 24.000 (11.263-27.000) Btu / h
- Cooling Capacity 7.03 (3.30-7.91) kWatt
- Heating Capacity 26.000 (9.577-30.500) Btu / h
- Heating Capacity 7.62 (2.81-8.94) kWatt
- Seasonal Efficiency (In accordance to EN14825)
- Cooling
- Pdesign 7.1 kW
- Energy Class A++
- SEER 6.3
- Middle Zone Heating
- Pdesign 6.2 kW
- Energy Class A+
- SCOP 4.1
- Warm Zone Heating
- Pdesign 6.3 kW
- Energy Class A+++
- SCOP 5.4
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 10.2 (4.2-12) Α
- Current Input Heating 8.5 (3.6-10.1) Α
- Power Input Cooling 2.32 (0.78-2.75) kW
- Power Input Heating 1.90 (0.61-2.30) kW
- Air Flow Volume (High / Medium / Low) 1.247/1.118/992 m³ / h
- Maximum Condensate Lift 1000 mm
- Noise Level Indoor unit (Low / Medium / High) 27/39.5/42.5/45.5 db(A)
- Noise Level Outdoor unit 60 db(A)
-
Sound Power
Indoor Unit /
Outdoor Unit 59/69 db(A) - Fuses 1x16 Α
- Command Cables 4 x 1.5 No x mm²
- Power Cables 3 x 2.5 No x mm²
- Dimensions WxDxH Panel 950x950x55 mm
- Dimensions WxDxH Indoor unit 830x830x205 mm
- Dimensions WxDxH Outdoor unit 890x342x673 mm
- Net Weight Panel / Indoor / Outdoor 6.0/21.6/43.9 kg
- Liquid line - Gas line 3/8" | 5/8"
- Maximum Distance - Horizontal 50
- Maximum Distance - Vertical 25
- Refrigerant / Charge R32/1.500 g
- Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
- Indoor Panel Model CP07
- V7CI-36WiFiR / U7RS-36
- Cooling Capacity 36.000 (9.200-39.000) Btu / h
- Cooling Capacity 10.55 (2.70-11.43) kWatt
- Heating Capacity 38.000 (9.500-42.000) Btu / h
- Heating Capacity 11.14(2.78-12.30) kWatt
- Seasonal Efficiency (In accordance to EN14825)
- Cooling
- Pdesign 10.5 kW
- Energy Class A++
- SEER 6.7
- Middle Zone Heating
- Pdesign 8.5 kW
- Energy Class A+
- SCOP 4.0
- Warm Zone Heating
- Pdesign 10.1 kW
- Energy Class A+++
- SCOP 5.1
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 17.50 (4.20-18.50) Α
- Current Input Heating 13.50 (3.50-17.50) Α
- Power Input Cooling 3.95 (0.90-4.20) kW
- Power Input Heating 3.70 (0.75-4.25) kW
- Air Flow Volume (High / Medium / Low) 1.700/1.550/1.380 m³ / h
- Maximum Condensate Lift 1000 mm
- Noise Level Indoor unit (Low / Medium / High) 39/44.5/47.5/50 db(A)
- Noise Level Outdoor unit 63 db(A)
-
Sound Power
Indoor Unit /
Outdoor Unit 64/70 db(A) - Fuses 1x25 Α
- Command Cables 4 x 1.5 No x mm²
- Power Cables 3 x 4.0 No x mm²
- Dimensions WxDxH Panel 950x950x55 mm
- Dimensions WxDxH Indoor unit 830x830x245 mm
- Dimensions WxDxH Outdoor unit 946x410x810 mm
- Net Weight Panel / Indoor / Outdoor 6.0/27.2/66.9 kg
- Liquid line - Gas line 3/8" | 5/8"
- Maximum Distance - Horizontal 75
- Maximum Distance - Vertical 30
- Refrigerant / Charge R32/2.400 g
- Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
- Indoor Panel Model CP07
- V7CI-42WiFiR / U7RS-42
- Cooling Capacity 41.000 (10.000-42.000) Btu / h
- Cooling Capacity 12.02(2.93-12.31) kWatt
- Heating Capacity 46.000 (11.500-48.000) Btu / h
- Heating Capacity 13.48(3.37-14.07) kWatt
- Seasonal Efficiency (In accordance to EN14825)
- Cooling
- Pdesign 12.1 kW
- Energy Class A++
- SEER 6.1
- Middle Zone Heating
- Pdesign 9.5 kW
- Energy Class A+
- SCOP 4.0
- Warm Zone Heating
- Pdesign 9.8 kW
- Energy Class A+++
- SCOP 5.1
- Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
- Current Input Cooling 18.80 (3.10-19.10) Α
- Current Input Heating 16.30 (3.40-19.00) Α
- Power Input Cooling 4.20 (0.68-4.35) kW
- Power Input Heating 3.70 (0.75-4.25) kW
- Air Flow Volume (High / Medium / Low) 1.900/1.750/1.600 m³ / h
- Maximum Condensate Lift 1000 mm
- Noise Level Indoor unit (Low / Medium / High) 38/46/48.5/51 db(A)
- Noise Level Outdoor unit 63 db(A)
-
Sound Power
Indoor Unit /
Outdoor Unit 66/72 db(A) - Fuses 1x25 Α
- Command Cables 4 x 1.5 No x mm²
- Power Cables 3 x 4.0 No x mm²
- Dimensions WxDxH Panel 950x950x55 mm
- Dimensions WxDxH Indoor unit 830x830x287 mm
- Dimensions WxDxH Outdoor unit 946x410x810 mm
- Net Weight Panel / Indoor / Outdoor 6.0/29.3/71.0 kg
- Liquid line - Gas line 3/8" | 5/8"
- Maximum Distance - Horizontal 75
- Maximum Distance - Vertical 30
- Refrigerant / Charge R32/2.800 g
- Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
- Indoor Panel Model CP07
- V7CI-50WiFiR / U7RT-50
- Cooling Capacity 48.000 (12.000-54.000) Btu / h
- Cooling Capacity 14.07(3.52-15.83) kWatt
- Heating Capacity 55.000 (14.000-59.000) Btu / h
- Heating Capacity 16.12(4.10-17.29) kWatt
- Seasonal Efficiency (In accordance to EN14825)
- Cooling
- Pdesign 14.0 kW
- Energy Class A++
- SEER 6.1
- Middle Zone Heating
- Pdesign 11.0 kW
- Energy Class A+
- SCOP 4.0
- Warm Zone Heating
- Pdesign 12.0 kW
- Energy Class A++
- SCOP 5.0
- Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
- Current Input Cooling 8.10 (1.80-10.20) Α
- Current Input Heating 8.00 (1.90-9.50) Α
- Power Input Cooling 4.65 (0.80-5.90) kW
- Power Input Heating 4.58 (0.90-5.50) kW
- Air Flow Volume (High / Medium / Low) 1.970/1.780/1.580 m³ / h
- Maximum Condensate Lift 1000 mm
- Noise Level Indoor unit (Low / Medium / High) 37.5/46.5/48.5/51 db(A)
- Noise Level Outdoor unit 63.5 db(A)
-
Sound Power
Indoor Unit /
Outdoor Unit 66/74 db(A) - Fuses 3x16 Α
- Command Cables 4 x 1.5 No x mm²
- Power Cables 5 x 2.5 No x mm²
- Dimensions WxDxH Panel 950x950x55 mm
- Dimensions WxDxH Indoor unit 830x830x287 mm
- Dimensions WxDxH Outdoor unit 952x415x1.333 mm
- Net Weight Panel / Indoor / Outdoor 6.0/29.3/103.7 kg
- Liquid line - Gas line 3/8" | 5/8"
- Maximum Distance - Horizontal 75
- Maximum Distance - Vertical 30
- Refrigerant / Charge R32/2.900 g
- Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
- Indoor Panel Model CP07
- V7CI-60WiFiR / U7iRT-60
- Cooling Capacity 53.000 (14.000-57.000) Btu / h
- Cooling Capacity 15.24 (4.10-16.71) kWatt
- Heating Capacity 62.000 (15.000-68.000) Btu / h
- Heating Capacity 18.17 (4.40-19.93) kWatt
- Seasonal Efficiency (In accordance to EN14825)
- Cooling
- Pdesign 15.3 kW
- Energy Class A++
- SEER 5.8
- Middle Zone Heating
- Pdesign 11.8 kW
- Energy Class A+
- SCOP 4.0
- Warm Zone Heating
- Pdesign 11.5 kW
- Energy Class A+++
- SCOP 4.9
- Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
- Current Input Cooling 8.8 (2.1-10.7) Α
- Current Input Heating 8.8 (2.1-10.8) Α
- Power Input Cooling 5.70 (1.00-6.25) kW
- Power Input Heating 5.70 (1.02-6.35) kW
- Air Flow Volume (High / Medium / Low) 2.000/1.850/1.650 m³ / h
- Maximum Condensate Lift 1000 mm
- Noise Level Indoor unit (Low / Medium / High) 40/48/50.5/53 db(A)
- Noise Level Outdoor unit 64 db(A)
-
Sound Power
Indoor Unit /
Outdoor Unit 66/75 db(A) - Fuses 3x16 Α
- Command Cables 4 x 1.5 No x mm²
- Power Cables 5 x 2.5 No x mm²
- Dimensions WxDxH Panel 950x950x55 mm
- Dimensions WxDxH Indoor unit 830x830x287 mm
- Dimensions WxDxH Outdoor unit 952x415x1.333 mm
- Net Weight Panel / Indoor / Outdoor 6.0/29.3/107.0 kg
- Liquid line - Gas line 3/8" | 5/8"
- Maximum Distance - Horizontal 75
- Maximum Distance - Vertical 30
- Refrigerant / Charge R32/3.000 g
- Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
- Indoor Panel Model CP07
Useful files of cassettes V7 series
Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Technical Specifications & Features
Find more
All you need to know about