Floor Ceiling V7 series - The units that adapt to the needs of your business!

  • Complete control of your air conditioning units from a single controller via Central Control Management
  • Hotel Menu for easy settings and efficient operation
  • Control your air conditioner from wherever you are and create the ideal conditions in your space
  • Effective removal of microbes
  • Smart sensor for ideal conditions exactly where you want them

Contact us

Eurovent"

The golden anti-corrosion coating of the outdoor unit’s heat exchanger provides enhanced protection against corrosion, helping to maintain the air conditioner over time. It is an ideal choice for areas with high humidity or exposure to factors that promote corrosion, such as islands and coastal regions.

Take advantage of the Weekly Scheduling feature and adjust the air conditioner's operating time according to your needs. The advanced wired controller displays fault codes and also provides the ability to activate a room temperature sensor on the controller instead of on the air conditioning unit.

Fresh air duct connection capability for improved air quality.

The plethora of options provided by the ON/OFF contact gives you the flexibility you need to manage your air conditioners, saving time. Install Door Switches or remote switches to turn units on or off easily and instantly.

Complete your building management system by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem including air conditioning, ventilation, lighting and security systems, ensuring full alignment with your building's needs. Enjoy the immediate, easy and efficient management of all these systems through a central system, thus improving performance and comfort in your building. *Separate connection kit purchase required

Create the desired conditions through the special On/Off setting of the fan and choose whether the fan will continue to operate even when the desired temperature in the room is reached.

Take complete control of your air conditioner and keep it running properly at all times thanks to the ability to connect a remote fault indicator.

ECO Mode automatically sets the air conditioner's temperature to 24°C and adjusts the fan to Auto mode during cooling. This helps further reduce operating costs while offering a more environmentally friendly way to maintain an ideal indoor climate.

With the GEAR function, you can limit the maximum efficiency of the unit, choosing between two operating levels, at 75% or 50% of maximum efficiency. Thus, you adapt the operation of the air conditioner to the needs of the space, helping to better control energy consumption.

The iClean function ensures the best air quality in your space, removing accumulated dust, mold and bacteria from inside the unit.

Set the device to automatically turn on/off within 24 hours.

Enjoy excellent temperature conditions and tranquil atmosphere. The advanced design of the unit, featuring larger gaps between air ducts and an improved fan tilt, facilitates airflow and ensures quiet, efficient performance. Additionally, Silent Mode further reduces noise levels, allowing you to enjoy a perfect atmosphere undisturbed.

With sleep mode, the air conditioner adjusts the room temperature for ideal conditions during the night or during hours that require absolute silence.

With Turbo Mode, the fastest cooling of the room is achieved.

Enjoy the flexibility of the Delay feature by postponing the weekly scheduling mode by up to 3 hours. Change your device settings for a specific day without changing your weekly scheduling settings.

Ensure the operation of your device in cooling or heating without interventions. With the lockable feature, the air conditioner's function cannot be changed, avoiding incorrect settings. Ideal for workplaces or hotel rooms.

Turn off the ability to use the wireless controller to adjust your air conditioner to ensure central control of the device from a single point. Suitable for business premises and hotels.

The temperature perceived by the sensor of the indoor unit may differ from the actual temperature of our space, due to the installation position of the unit at a high height. With this function we minimize the difference and achieve the best conditions in the space.

The sensor of the indoor element controls the internal fan and prevents cold air from entering the room when starting in heating mode.

The air conditioner's sophisticated control design provides effective and efficient cooling operation in areas where special conditions are required, even at -15°C.

With the special design of the air conditioner, efficient heating is achieved even when extremely low temperatures prevail. Enjoy an ideal atmosphere even at -15°C.

In the event of unusual behavior, the unit will automatically shut down to protect the system. After a while, a protection code will appear on the screen for immediate repair.

In the event of a power failure, the air conditioning unit will automatically restart according to the previous settings.

The indoor unit will display an error code "EC" and stop automatically as soon as a coolant leak is diagnosed to protect the compressor from overheating.

Enjoy a quieter and more comfortable environment by turning off the sound of the keys and the air conditioner display.

Turn on lock mode to prevent children from changing settings or using them.

The fans of the indoor and outdoor unit, as well as the compressor, feature DC Inverter technology, allowing for smooth and efficient adjustment of the air conditioner's operation to suit the needs of the space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

  • V7KI-18WiFiR / U7RS-18
  • Cooling Capacity 18.000 (9.250-20.000) Btu / h
  • Cooling Capacity 5.28 (2.71-5.86) kWatt
  • Heating Capacity 19.000 (8.250-21.500) Btu / h
  • Heating Capacity 5.57 (2.42-6.30) kWatt
  • Seasonal Efficiency (In accordance to EN14825)
  • Cooling
  • Pdesign 5.4 kW
  • Energy Class A++
  • SEER 6.2
  • Heating Middle Zone
  • Pdesign 4.0 kW
  • Energy Class A+
  • SCOP 4.0
  • Heating Warm Zone
  • Pdesign 5.1 kW
  • Energy Class A+++
  • SCOP 5.1
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 6.00 (3.20-9.00) Α
  • Current Input Heating 6.60 (2.70-7.30) Α
  • Power Input Cooling 1.45 (0.67-2.03) kW
  • Power Input Heating 1.50 (0.54-1.64) kW
  • Air Flow Volume (High / Medium / Low) 958/839/723 m³ / h
  • Noise Level Indoor unit (Silent/ Low / Medium / High) 24/36.5/41/43.5 db(A)
  • Noise Level Outdoor unit 59 db(A)
  • Sound Power Level Indoor / Outdoor unit 59/65 db(A)
  • Fuses 1x16 Α
  • Signal Wires 4x1.5 No x mm²
  • Dimensions Indoor unit (WxDxH) 1.068x675x235 mm
  • Dimensions Outdoor unit (WxDxH) 805x330x554 mm
  • Net Weight - Indoor/Outdoor Unit 28.0/32.5 kg
  • Liquid line - Gas line 1/4" | 1/2"
  • Refrigerant / Charge R32/1.150 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
  • V7KI-24WiFiR / U7iRS-24
  • Cooling Capacity 24.000 (10.990-26.500) Btu / h
  • Cooling Capacity 7.03 (3.22-7.77) kWatt
  • Heating Capacity 26.000 (9.280-28.285) Btu / h
  • Heating Capacity 7.62 (2.72-8.29) kWatt
  • Seasonal Efficiency (In accordance to EN14825)
  • Cooling
  • Pdesign 7.1 kW
  • Energy Class A++
  • SEER 6.3
  • Heating Middle Zone
  • Pdesign 5.9 kW
  • Energy Class A+
  • SCOP 4.1
  • Heating Warm Zone
  • Pdesign 5.7 kW
  • Energy Class A+++
  • SCOP 5.4
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 10.54 (3.90-12.10) Α
  • Current Input Heating 8.70 (3.50-10.60) Α
  • Power Input Cooling 2.30 (0.75 - 2.73) kW
  • Power Input Heating 1.98 (0.65 - 2.94) kW
  • Air Flow Volume (High / Medium / Low) 1.192/1.023/853 m³ / h
  • Noise Level Indoor unit (Silent/ Low / Medium / High) 32/43/46/49 db(A)
  • Noise Level Outdoor unit 60 db(A)
  • Sound Power Level Indoor / Outdoor unit 55/67 db(A)
  • Fuses 1x16 Α
  • Signal Wires 4x1.5 No x mm²
  • Supply Pipes 3x2.5 Noxmm²
  • Dimensions Indoor unit (WxDxH) 1.068x675x235 mm
  • Dimensions Outdoor unit (WxDxH) 890x342x673 mm
  • Net Weight - Indoor/Outdoor Unit 28.0/41.9 kg
  • Liquid line - Gas line 3/8" | 5/8"
  • Maximum Distance - Horizontal 50
  • Maximum Distance - Vertical 25
  • Refrigerant / Charge R32/1.400 g
  • Refrigerant Volume per Additional Meter of Pipe 24 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
  • V7KI-36WiFiR / U7RS-36
  • Cooling Capacity 36.000 (9.300-39.000) Btu / h
  • Cooling Capacity 10.55 (2.73-11.43) kWatt
  • Heating Capacity 40.000 (9.600-43.600) Btu / h
  • Heating Capacity 11.72 (2.78-12.78) kWatt
  • Seasonal Efficiency (In accordance to EN14825)
  • Cooling
  • Pdesign 10.5 kW
  • Energy Class A++
  • SEER 6.4
  • Heating Middle Zone
  • Pdesign 8.6 kW
  • Energy Class A+
  • SCOP 4.1
  • Heating Warm Zone
  • Pdesign 10.2 kW
  • Energy Class A+++
  • SCOP 5.1
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 17.0 (4.2-19.0) Α
  • Current Input Heating 15.0 (3.5-17.5) Α
  • Power Input Cooling 3.90 (0.90-4.25) kW
  • Power Input Heating 3.35 (0.80-3.95) kW
  • Air Flow Volume (High / Medium / Low) 1.955/1.728/1.504 m³ / h
  • Noise Level Indoor unit (Silent/ Low / Medium / High) 37/44/48.5/50 db(A)
  • Noise Level Outdoor unit 63 db(A)
  • Sound Power Level Indoor / Outdoor unit 65/70 db(A)
  • Fuses 1x25 Α
  • Signal Wires 4x1.5 No x mm²
  • Dimensions Indoor unit (WxDxH) 1.650x675x235 mm
  • Dimensions Outdoor unit (WxDxH) 946x410x810 mm
  • Net Weight - Indoor/Outdoor Unit 41.5/66.9 kg
  • Liquid line - Gas line 3/8" | 5/8"
  • Refrigerant / Charge R32/2.400 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
  • V7KI-50WiFiR / U7RT-50
  • Cooling Capacity 48.000 (12.000-52.000) Btu / h
  • Cooling Capacity 14.07 (3.52-15.24) kWatt
  • Heating Capacity 55.000 (14.000-58.000) Btu / h
  • Heating Capacity 16.12 (4.10-17.00) kWatt
  • Seasonal Efficiency (In accordance to EN14825)
  • Cooling
  • Pdesign 14.0 kW
  • Energy Class A++
  • SEER 6.1
  • Heating Middle Zone
  • Pdesign 11.2 kW
  • Energy Class A+
  • SCOP 4.0
  • Heating Warm Zone
  • Pdesign 11.7 kW
  • Energy Class A+++
  • SCOP 5.1
  • Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
  • Current Input Cooling 8.8 (1.9-10.3) Α
  • Current Input Heating 8.9 (2.1-10.5) Α
  • Power Input Cooling 5.00 (0.90-5.95) kW
  • Power Input Heating 5.10 (1.00-6.05) kW
  • Air Flow Volume (High / Medium / Low) 2.100/1.850/1.600 m³ / h
  • Noise Level Indoor unit (Silent/ Low / Medium / High) 36/45/50/53 db(A)
  • Noise Level Outdoor unit 63.5 db(A)
  • Sound Power Level Indoor / Outdoor unit 67/74 db(A)
  • Fuses 3x16 Α
  • Signal Wires 4x1.5 No x mm²
  • Dimensions Indoor unit (WxDxH) 1.650x675x235 mm
  • Dimensions Outdoor unit (WxDxH) 952x415x1.333 mm
  • Net Weight - Indoor/Outdoor Unit 41.7/103.7 kg
  • Liquid line - Gas line 3/8" | 5/8"
  • Refrigerant / Charge R32/2.900 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 °C
  • V7KI-60WiFiR / U7iRT-60
  • Cooling Capacity 52.000 (14.000-55.000) Btu / h
  • Cooling Capacity 15.24 (4.10-16.12) kWatt
  • Heating Capacity 62.000 (15.000-66.000) Btu / h
  • Heating Capacity 18.17 (4.40-19.35) kWatt
  • Seasonal Efficiency (In accordance to EN14825)
  • Cooling
  • Pdesign 15.3 kW
  • Energy Class A+
  • SEER 5.8
  • Heating Middle Zone
  • Pdesign 11.8 kW
  • Energy Class A+
  • SCOP 4.0
  • Heating Warm Zone
  • Pdesign 11.5 kW
  • Energy Class A+++
  • SCOP 5.1
  • Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
  • Current Input Cooling 8.90 (3.1-10.8) Α
  • Current Input Heating 10.50 (2.2-12) Α
  • Power Input Cooling 5.90 (1.10 - 6.50) kW
  • Power Input Heating 5.95 (1.12 - 6.35) kW
  • Air Flow Volume (High / Medium / Low) 2.200/1.950/1.650 m³ / h
  • Noise Level Indoor unit (Silent/ Low / Medium / High) 36/42/50/52 db(A)
  • Noise Level Outdoor unit 64 db(A)
  • Sound Power Level Indoor / Outdoor unit 67/75 db(A)
  • Fuses 3x16 Α
  • Signal Wires 4x1.5 No x mm²
  • Supply Pipes 5x2.5 Noxmm²
  • Dimensions Indoor unit (WxDxH) 1.650x675x235 mm
  • Dimensions Outdoor unit (WxDxH) 980x415x975 mm
  • Net Weight - Indoor/Outdoor Unit 42.3/92.0 kg
  • Liquid line - Gas line 3/8" | 5/8"
  • Maximum Distance - Horizontal 75
  • Maximum Distance - Vertical 30
  • Refrigerant / Charge R32/3.200 g
  • Refrigerant Volume per Additional Meter of Pipe 24 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50 / -20~24 °C