Aria AR5 Air Conditioner Series with A+++* Energy Class in Heating (Warm Climate Zone), Ionizer, HEPA Sterilization Filter, Triple-Action Filter & Follow Me Function!

  • A+++* Energy Class in heating (Warm Climate Zone) with SCOP from 5.1 to 5.4
  • A sense of freshness and effective removal of harmful particles thanks to the Ionizer function
  • Removal of dust from the air and reduction of the likelihood of allergies and illnesses with the HEPA Sterilization Filter
  • Improved air quality with the Triple-Action Filter
  • Ideal conditions exactly where you want them with the Follow Me Function

**Based on the applicable table of Regulation (EU) 626/2011.

Ensure uniform distribution of air in all directions and coverage of even the most difficult parts of the room. The design of the air conditioner series allows both horizontal and vertical movement of the blinds. Take peace of mind and enjoy absolute comfort in every part of your home.

Through the smart Wi-Fi function and the Inventor Control application with voice commands, you create the environment you want, from wherever you are and whenever it suits you. Download the application for free and easily and quickly adjust your air conditioner from your mobile phone.

The golden anti-corrosion coating of the outdoor unit’s heat exchanger provides enhanced protection against corrosion, helping to maintain the air conditioner over time. It is an ideal choice for areas with high humidity or exposure to factors that promote corrosion, such as islands and coastal regions.

Hotel Menu is a set of features and settings, specially designed for small and large hotel businesses. It contributes to the easy setup and efficient operation of air conditioners.

Enjoy excellent temperature conditions and tranquil atmosphere. The advanced design of the unit, featuring larger gaps between air ducts and an improved fan tilt, facilitates airflow and ensures quiet, efficient performance. Additionally, Silent Mode further reduces noise levels, allowing you to enjoy a perfect atmosphere undisturbed.

The self-cleaning function thoroughly cleans the indoor air conditioner unit, removing dust, pollen and microorganisms that pass through it and remain inside. At the same time, it reduces unwanted moisture accumulated during cooling operation in summer. To ensure optimal performance and proper maintenance of the unit, it is recommended that internal cleaning be carried out once a month.

Control up to 64 air conditioning units from one controller! Turn the air conditioning unit on and off, adjust the room temperature and select the mode you want. Ideal for hotel units, office buildings, etc.

The plethora of options provided by the ON/OFF contact gives you the flexibility you need to manage your air conditioners, saving time. Install Door Switches or remote switches to turn units on or off easily and instantly.

1W power consumption in standby mode.

The advanced air filter provides up to 40% more dust absorption, protecting the indoor unit more effectively and ensuring fresh air in your space.

The 8°C mode is ideal for areas that remain unheated for long periods of time during the winter. When activated, the air conditioner works to keep the room temperature at around 8°C, helping to protect the space and objects from very low temperatures.

With the special design of the air conditioner, efficient heating is achieved even when extremely low temperatures prevail. Enjoy an ideal atmosphere even at -15°C.

The air conditioner's sophisticated control design provides effective and efficient cooling and heating operation in areas where special conditions are required, even at -15°C. Ensure desired temperature levels, even in the harshest weather conditions.

With sleep mode, the air conditioner adjusts the room temperature for ideal conditions during the night or during hours that require absolute silence.

Set the device to automatically turn on/off within 24 hours.

The sensor of the indoor element controls the internal fan and prevents cold air from entering the room when starting in heating mode.

With Turbo Mode, the fastest cooling of the room is achieved.

Enjoy a quieter and more comfortable environment by turning off the sound of the keys and the air conditioner display.

Up to 12 stages of internal fan speeds offer comfortable airflow in the room.

5-speed fan for stable operation.

The temperature perceived by the sensor of the indoor unit may differ from the actual temperature of our space, due to the installation position of the unit at a high height. With this function we minimize the difference and achieve the best conditions in the space.

This function ensures the correct distribution of cold or hot air in your space.

The horizontal louver will automatically move to the same position you set it in the last time you turned on the unit.

The drain duct can be connected to the left or right side of the indoor unit for easy installation.

In the event of a power failure, the air conditioning unit will automatically restart according to the previous settings.

In the event of unusual behavior, the unit will automatically shut down to protect the system. After a while, a protection code will appear on the screen for immediate repair.

In the event that the temperature sensor has a problem, a protection code will appear on the air conditioner display. The air conditioner unit will continue to operate until the fault is resolved.

The indoor unit will display an error code "EC" and stop automatically as soon as a coolant leak is diagnosed to protect the compressor from overheating.

Ensure the smooth operation of your air conditioner through intelligent de-icing. In the event of ice formation, the compressor will automatically stop and the fan will continue to operate until it disappears completely.

The fans of the indoor and outdoor unit, as well as the compressor, feature DC Inverter technology, allowing for smooth and efficient adjustment of the air conditioner's operation to suit the needs of the space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

  • AR5VI-09WFI/ AR5VO-09
  • Cooling Capacity 9.000 (3.500-11.000) Btu / h
  • Cooling Capacity Range 2.64 (1.03-3.22) kWatt
  • Heating Capacity 10.000 (2.800-11.500) Btu / h
  • Heating Capacity 2.93 (0.82-3.37) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 2.7 kW
  • Energy Class A++
  • SEER 6.9
  • Energy Consumption 137 kWh / year
  • Heating Middle Zone
  • Pdesign 2.7 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 946 kWh / year
  • Heating Warm Zone
  • Pdesign 2.5 kW
  • Energy Class A+++
  • SCOP 5.3
  • Energy Consumption 661 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 3.22 (0.35-4.78) Α
  • Current Input Heating 3.40 (0.32-4.32) Α
  • Power Input Cooling 0.74 (0.08-1.10) kW
  • Power Input Heating 0.78 (0.07-0.99) kW
  • Air Flow Volume
    (High/Medium/Low)
    416/309/230 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 23/26/32/39 db(A)
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 56 db(A)
  • Sound Power Level Outdoor Unit 63 db(A)
  • Dehumidifying Volume 1.2 L/h
  • Dehumidifying Volume 28.8 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 3 / 8”
  • Fuses 10 A
  • Signal Wires 5x1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    722x187x290 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    720x270x495 mm
  • Net Weight Indoor / Outdoor 7.3/23.2 kg
  • Refrigerant / Charge R32/550 g
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C
  • AR5VI-12WFI/ AR5VO-12
  • Cooling Capacity 12.000 (2.800-14.200) Btu / h
  • Cooling Capacity Range 3.52 (0.82-4.16) kWatt
  • Heating Capacity 13.000 (2.900-16.300) Btu / h
  • Heating Capacity 3.81 (0.85-4.78) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A++
  • SEER 7.0
  • Energy Consumption 175 kWh / year
  • Heating Middle Zone
  • Pdesign 2.9 kW
  • Energy Class A+
  • SCOP 4.1
  • Energy Consumption 992 kWh / year
  • Heating Warm Zone
  • Pdesign 2.5 kW
  • Energy Class A+++
  • SCOP 5.4
  • Energy Consumption 649 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 4.96 (0.40-6.90) Α
  • Current Input Heating 4.68 (0.70-7.40) Α
  • Power Input Cooling 1.09 (0.10-1.60) kW
  • Power Input Heating 1.05 (0.16-1.71) kW
  • Air Flow Volume
    (High/Medium/Low)
    584/477/395 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 23/26/32/39 db(A)
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 55 db(A)
  • Sound Power Level Outdoor Unit 63 db(A)
  • Dehumidifying Volume 1.6 L/h
  • Dehumidifying Volume 38.4 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 3 / 8”
  • Fuses 10 A
  • Signal Wires 5x1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    802x189x297 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    720x270x495 mm
  • Net Weight Indoor / Outdoor 8.6/23.2 kg
  • Refrigerant / Charge R32/550 g
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C
  • AR5VI-18WFI/ AR5VO-18
  • Cooling Capacity 18.000 (11.570-20.130) Btu / h
  • Cooling Capacity Range 5.28 (3.39-5.90) kWatt
  • Heating Capacity 19.000 (10.580-19.960) Btu / h
  • Heating Capacity 5.57 (3.10-5.85) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 5.3 kW
  • Energy Class A++
  • SEER 7.0
  • Energy Consumption 265 kWh / year
  • Heating Middle Zone
  • Pdesign 4.1 kW
  • Energy Class A+
  • SCOP 4.1
  • Energy Consumption 1.401 kWh / year
  • Heating Warm Zone
  • Pdesign 4.5 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 1.308 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 6.70 (2.40-9.00) Α
  • Current Input Heating 6.50 (3.40-8.70) Α
  • Power Input Cooling 1.55 (0.56-2.05) kW
  • Power Input Heating 1.50 (0.78-2.00) kW
  • Air Flow Volume
    (High/Medium/Low)
    730/500/420 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 23/28/33.5/43 db(A)
  • Sound Power Level Outdoor Unit 55.5 db(A)
  • Sound Power Level Indoor Unit 57 db(A)
  • Sound Power Level Outdoor Unit 65 db(A)
  • Dehumidifying Volume 2.0 L/h
  • Dehumidifying Volume 48.0 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 1 / 2”
  • Fuses 16 A
  • Signal Wires 5x1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    965x215x319 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    805x330x554 mm
  • Net Weight Indoor / Outdoor 10.9/33.5 kg
  • Refrigerant / Charge R32/1.100 g
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C
  • AR5VI-24WFI/ AR5VO-24
  • Cooling Capacity 24.000 (7.200-28.000) Btu / h
  • Cooling Capacity Range 7.03 (2.11-8.21) kWatt
  • Heating Capacity 25.000 (5.300-28.000) Btu / h
  • Heating Capacity 7.33 (1.55-8.21) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 7.0 kW
  • Energy Class A++
  • SEER 6.5
  • Energy Consumption 377 kWh / year
  • Heating Middle Zone
  • Pdesign 4.9 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1.717 kWh / year
  • Heating Warm Zone
  • Pdesign 5.3 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 1.545 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 10.90 (1.80-13.90) Α
  • Current Input Heating 9.30 (1.30-13.50) Α
  • Power Input Cooling 2.51 (0.42-3.20) kW
  • Power Input Heating 2.13 (0.30-3.10) kW
  • Air Flow Volume
    (High/Medium/Low)
    1.020/830/640 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 25/30.5/41.0/47 db(A)
  • Sound Power Level Outdoor Unit 60.5 db(A)
  • Sound Power Level Indoor Unit 64 db(A)
  • Sound Power Level Outdoor Unit 67 db(A)
  • Dehumidifying Volume 2.8 L/h
  • Dehumidifying Volume 67.2 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 3 / 8” / 5 / 8”
  • Fuses 16 A
  • Signal Wires 5x2.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.080x226x335 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    890x342x673 mm
  • Net Weight Indoor / Outdoor 13.7/43.9 kg
  • Refrigerant / Charge R32/1.450 g
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C

Useful files of the Aria (AR5) series of air conditioners

Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Technical Specifications & Features

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …

Thank you for your registration!