- Based on the applicable table of Regulation (EU) 626/2011.
Features/ Technologies
Remote On/Off
The plethora of options provided by the ON/OFF contact gives you the flexibility you need to manage your air conditioners, saving time. Install Door Switches or remote switches to turn units on or off easily and instantly.
Central Control
Control up to 64 air conditioning units from one controller! Turn the air conditioning unit on and off, adjust the room temperature and select the mode you want. Ideal for hotel units, office buildings, etc.
BMS Connectivity (Optional)
Complete your building management system by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem including air conditioning, ventilation, lighting and security systems, ensuring full alignment with your building's needs. Enjoy the immediate, easy and efficient management of all these systems through a central system, thus improving performance and comfort in your building. *Separate connection kit purchase required
Ultra Silence Mode
Activate the Ultra Silence Mode and enjoy an absolute feeling of pure silence in your room.
Low Ambient Cooling at -20°C
The air conditioner's sophisticated control design provides effective and efficient cooling operation in areas where special conditions are required, even at -20°C.
Low Ambient Heating at -20°C
With the special design of the air conditioner, effective heating is achieved even when extremely low temperatures prevail. Enjoy an ideal atmosphere even at -20°C.
High Density Air Dust Filter
The advanced air filter provides up to 40% more dust absorption, protecting the indoor unit more effectively and ensuring fresh air in your space.
24-hour Timer
Set the device to automatically turn on/off within 24 hours.
Sleep Mode
With sleep mode, the air conditioner adjusts the room temperature for ideal conditions during the night or during hours that require absolute silence.
Auto Swing Louver
This function ensures the correct distribution of cold or hot air in your space.
Louver Position Memory
The horizontal louver will automatically move to the same position you set it in the last time you turned on the unit.
Anti-Cold Air Function
The sensor of the indoor element controls the internal fan and prevents cold air from entering the room when starting in heating mode.
Turbo Mode
With Turbo Mode, the fastest cooling of the room is achieved.
Auto Restart
In the event of a power failure, the air conditioning unit will automatically restart according to the previous settings.
Auto Error Diagnosis
In the event of unusual behavior, the unit will automatically shut down to protect the system. After a while, a protection code will appear on the screen for immediate repair.
Refrigerant Leakage Detect
The indoor unit will display an error code "EC" and stop automatically as soon as a coolant leak is diagnosed to protect the compressor from overheating.
Two-way Draining
The drain duct can be connected to the left or right side of the indoor unit for easy installation.
All DC Inverter
The fans of the indoor and outdoor unit, as well as the compressor, feature DC Inverter technology, allowing for smooth and efficient adjustment of the air conditioner's operation to suit the needs of the space.
R32 ECO Refrigerant
The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.
Technical Specifications
- DR2VI-09WFI/ DR2VO-09
- Cooling Capacity 9.000 (2.730-12.620) Btu / h
- Cooling Capacity 2.6 (0.8-3.2) kWatt
- Heating Capacity 11.000 (2.730-14.330) Btu / h
- Heating Capacity 3.2 (0.8-4.2) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 2.6 kW
- Energy Class A+++
- SEER 8.5
- Annual Power Consumption 107 kWh / year
- Heating Middle Zone
- Pdesign 2.4 kW
- Energy Class A++
- SCOP 4.6
- Annual Power Consumption 731 kWh / year
- Heating Warm Zone
- Pdesign 2.3 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 631 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 2.9 (0.9-6.7) Α
- Current Input - Heating 3.6 (1.3-7.2) Α
- Power Input - Cooling 0.65 (0.2-1.5) W
- Power Input - Heating 0.8 (0.3-1.6) W
- Air Flow Volume (Turbo/High/Medium/Low) 650/600/500/450 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 20/25/30/35 db(A) - Noise Level - Outdoor unit 47 db(A)
- Sound Power Level - Indoor unit 54 db(A)
- Sound Power Level - Outdoor unit 59 db(A)
- Dehumidifying Volume 1.2 L/h
- Dehumidifying Volume 28.8 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 3 / 8”
- Fuses 10 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 887x211x281 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 10.0/29.0 kg - Refrigerant/Charge R32/650 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
- DR2VI-12WFI/ DR2VO-12
- Cooling Capacity 12.000 (3.410-13.650) Btu / h
- Cooling Capacity 3.5 (1.0-4.0) kWatt
- Heating Capacity 14.500 (3.410-17.740) Btu / h
- Heating Capacity 4.2 (1.0-5.2) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 3.5 kW
- Energy Class A+++
- SEER 8.5
- Annual Power Consumption 144 kWh / year
- Heating Middle Zone
- Pdesign 2.8 kW
- Energy Class A++
- SCOP 4.6
- Annual Power Consumption 854 kWh / year
- Heating Warm Zone
- Pdesign 2.8 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 768 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 3.9 (1.4-6.7) Α
- Current Input - Heating 5.0 (1.3-7.2) Α
- Power Input - Cooling 0.87 (0.3-1.5) W
- Power Input - Heating 1.1 (0.5-1.6) W
- Air Flow Volume (Turbo/High/Medium/Low) 700/650/550/500 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 22/29/33/38 db(A) - Noise Level - Outdoor unit 48 db(A)
- Sound Power Level - Indoor unit 56 db(A)
- Sound Power Level - Outdoor unit 61 db(A)
- Dehumidifying Volume 1.6 L/h
- Dehumidifying Volume 38.4 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 3 / 8”
- Fuses 10 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 887x211x281 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 10.0/31.5 kg - Refrigerant/Charge R32/940 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
- DR2VI32-18WFI/ DR2VO32-18
- Cooling Capacity 18.000 (4.430-19.790) Btu / h
- Cooling Capacity 5.0 (1.30-5.80) kWatt
- Heating Capacity 18.150 (4.770-20.470) Btu / h
- Heating Capacity 5.2 (1.4-6.0) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 5.0 kW
- Energy Class A++
- SEER 6.1
- Annual Power Consumption 287 kWh / year
- Heating Middle Zone
- Pdesign 4.6 kW
- Energy Class A+
- SCOP 4.0
- Annual Power Consumption 1.610 kWh / year
- Heating Warm Zone
- Pdesign 4.6 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 1.263 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 6.5 (1.8-8.9) Α
- Current Input - Heating 6.3 (2.3-11.3) Α
- Power Input - Cooling 1.46 (0.4-2.0) W
- Power Input - Heating 1.4 (0.5-2.5) W
- Air Flow Volume (Turbo/High/Medium/Low) 1.000/900/800/600 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 30/35/40/44 db(A) - Noise Level - Outdoor unit 53 db(A)
- Sound Power Level - Indoor unit 59 db(A)
- Sound Power Level - Outdoor unit 65 db(A)
- Dehumidifying Volume 2.0 L/h
- Dehumidifying Volume 48.0 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 1 / 2”
- Fuses 16 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 1.030x233x322 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 13.0/32.7 kg - Refrigerant/Charge R32/900 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
- DR2VI32-24WFI/ DR2VO32-24
- Cooling Capacity 24.000 (7.500-29.000) Btu / h
- Cooling Capacity 7.0 (2.2-8.5) kWatt
- Heating Capacity 28.000 (8.190-34.120) Btu / h
- Heating Capacity 8.1 (2.40-10.0) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 7.0 kW
- Energy Class A++
- SEER 7.1
- Annual Power Consumption 350 kWh / year
- Heating Middle Zone
- Pdesign 5.6 kW
- Energy Class A+
- SCOP 4.0
- Annual Power Consumption 1.963 kWh / year
- Heating Warm Zone
- Pdesign 5.6 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 1.537 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 9.6 (3.2-13) Α
- Current Input - Heating 9.7 (3.2-13) Α
- Power Input - Cooling 2.16 (0.7-2.9) W
- Power Input - Heating 2.18 (0.7-2.9) W
- Air Flow Volume (Turbo/High/Medium/Low) 1.300/1.200/1.000/850 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 30/37/43/47 db(A) - Noise Level - Outdoor unit 52 db(A)
- Sound Power Level - Indoor unit 60 db(A)
- Sound Power Level - Outdoor unit 65 db(A)
- Dehumidifying Volume 2.8 L/h
- Dehumidifying Volume 67.2 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 1 / 2”
- Fuses 16 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 1.115x248x336 mm -
Dimensions - Outdoor unit
(WxDxH) 890x353x697 mm -
Net Weight -
Indoor/Outdoor 16.0/47.3 kg - Refrigerant/Charge R32/1.200 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
Useful files of the Dark series of air conditioners
Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Technical Specifications & Features
Find more
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …