Consoles - V7 series – The best choice for your business that offers excellent performance, energy saving and ultimate flexibility!

  • Double Air Outlet for excellent cooling and heating performance and energy savings
  • Scheduling the operation of the air conditioner according to your needs
  • Absolute comfort in setting the air-conditioner from wherever you are thanks to the smart remote management via Wi-Fi
  • Follow Me Mode for ideal conditions where you want them
  • Energy and cost savings thanks to the ECO Function
Eurovent"

Become an Inventor Partner

Inventor air conditioners present the innovative air-conditioning unit management "HOTEL MENU". The HOTEL MENU is a set of features specifically designed to help better and more economical operation of air conditioners installed in hotel units.

The centralized multi-functional device can control up to 64 indoor units within a maximum connection length of 1200m. Control your air conditioner, set the temperature you want and select the mode you desire. Ideal for hotel & business units. *Requires separate purchase of connection kit

The variety of options provided by the pre-installed ON/OFF contact gives you the flexibility you need to manage your air conditioners, while saving time and energy. Install Door Switch or remote switches to turn units on or off easily and instantly. *Requires separate purchase of connection kit

Complete your connected products portfolio by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem that includes air conditioning, ventilation, lighting, and security systems, fully alignment with your building's needs. Enjoy quick, easy, and efficient management of all these different systems through central management and achieve optimum efficiency and comfort in your building. *Requires separate purchase of connection kit

With the GEAR function you achieve great energy savings, limiting the maximum consumption of the unit. You can adjust the performance in two stages, at 75% of maximum efficiency and 50%. Take care of the right temperature in your space, reducing operating costs.

The iClean function ensures the best air quality in your space, removing accumulated dust, mold and bacteria from inside the unit.

The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!

Prevent potential weather damages in places that are not heated and pose risks during the winter. Enable the 8°C function and the air conditioner only heats the room as needed while maintaining a stable room temperature of 8°C.

With the On / Off switch, you can choose whether you want the fan to continue operating after the unit is turned off or stop.

Take the whole control of you unit! Thanks to the error code that will appear if an error occurs, you can always be safe and sure for the appropriate and most efficient operation of your air conditioner.

  • MODEL V7LI-12WiFiR/U7RS-12
  • Cooling Capacity 12.000 (2.600-14.500) Btu / h
  • Cooling Capacity 3.52 (0.76-4.25) kWatt
  • Heating Capacity 13.000 (1.550-16.000) Btu / h
  • Heating Capacity 3.81 (0.45-4.69) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A++
  • SEER 7.3
  • Heating Middle Zone
  • Pdesign 2.6 kW
  • Energy Class A+
  • SCOP 4.0
  • Heating Warm Zone
  • Pdesign 3.4 kW
  • Energy Class A+++
  • SCOP 5.5
  • Voltage/Frequency/Phase 220-240/50/1 V / Hz / Ph
  • Current Input - Cooling 4.5 (1.40-5.90) Α
  • Current Input - Heating 4.4 (1.25-5.95) Α
  • Power Input - Cooling 1.00 (0.17-1.35) kW
  • Power Input - Heating 0.98 (0.15-1.30) kW
  • Air Flow Volume (High/Medium/Low) 512/480/370 m³ / h
  • Noise Level - Indoor unit
    (Low/Medium/High)
    21/27/34/37 db(A)
  • Noise Level - Outdoor unit 54 db(A)
  • Sound Power Level - Indoor/Outdoor Unit 55/63 db(A)
  • Power Supply Wire Outdoor / Fuses 3x2.5 / 1x16 No x mm² / Α
  • Signal Wires 4x1.5 No x mm²
  • Dimensions - Indoor Unit
    (WxDxH)
    794x206x621 mm
  • Dimensions - Outdoor Unit
    (WxDxH)
    765x303x555 mm
  • Net Weight - Indoor/Outdoor Unit 14.9/26.6 kg
  • Compressor type ROTARY Pa
  • Liquid Line |Gas Line 1/4" | 3/8"
  • Refrigerant/Charge R32/710 g
  • Operation Temperature Range -
    Cooling/Heating
    -15~50 / -15~24 °C
  • MODEL V7LI-18WiFiR/U7RS-18
  • Cooling Capacity 17.000 (9.000-19.000) Btu / h
  • Cooling Capacity 4.98 (2.64-5.57) kWatt
  • Heating Capacity 18.000 (7.500-21.500) Btu / h
  • Heating Capacity 5.28 (2.20-6.30) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign 5.0 kW
  • Energy Class A++
  • SEER 6.7
  • Heating Middle Zone
  • Pdesign 4.0 kW
  • Energy Class A+
  • SCOP 4.0
  • Heating Warm Zone
  • Pdesign 5.0 kW
  • Energy Class A++
  • SCOP 5.0
  • Voltage/Frequency/Phase 220-240/50/1 V / Hz / Ph
  • Current Input - Cooling 6.7 (2.95-8.70) Α
  • Current Input - Heating 6.4 (2.75-8.50) Α
  • Power Input - Cooling 1.50 (0.65-1.95) kW
  • Power Input - Heating 1.42 (0.60-1.90) kW
  • Air Flow Volume (High/Medium/Low) 560/480/400 m³ / h
  • Noise Level - Indoor unit
    (Low/Medium/High)
    24/32/38/41 db(A)
  • Noise Level - Outdoor unit 55 db(A)
  • Sound Power Level - Indoor/Outdoor Unit 56/64 db(A)
  • Power Supply Wire Outdoor / Fuses 3x2.5 / 1x16 No x mm² / Α
  • Signal Wires 4x1.5 No x mm²
  • Dimensions - Indoor Unit
    (WxDxH)
    794x206x621 mm
  • Dimensions - Outdoor Unit
    (WxDxH)
    805x330x554 mm
  • Net Weight - Indoor/Outdoor Unit 14.9/32.5 kg
  • Compressor type ROTARY Pa
  • Liquid Line |Gas Line 1/4" | 1/2"
  • Refrigerant/Charge R32/1.150 g
  • Operation Temperature Range -
    Cooling/Heating
    -15~50 / -15~24 °C

Set the unit to start and stop automatically in a 24h period.

Enjoy excellent temperature conditions and tranquil atmosphere. The advanced design of the unit, featuring larger gaps between air ducts and an improved fan tilt, facilitates airflow and ensures quiet, efficient performance. Additionally, Silent Mode further reduces noise levels, allowing you to enjoy a perfect atmosphere undisturbed.

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Enjoy the flexibility offered by the Delay function, postponing the activation of the weekly schedule for up to 3 hours. Change your device settings for a specific day without changing your weekly schedule settings.

Ensure the operation of your appliance in cooling or heating without interference. With the locking feature, the operation of the air conditioner cannot be changed, avoiding incorrect settings, and offering a more correct and economical operation. Ideal for workplaces or hotel rooms.

Turn off the ability to use the wireless controller to adjust your air conditioner to ensure central control of the device from a single point. Suitable for business premises and hotels.

The perceived temperature by the indoor unit sensor may vary from the real temperature of the room, due to the position of the unit. Thanks to this function you can minimize the difference and achieve better conditions in your place.

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation.

The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.

Excellent heating performance even at the most demaning regions with low temperature levels. Ensure the prefered temperature conditions, even at -15°C and enjoy ideal conditions in your place.

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

Media Library for Consoles

User, Installation & RC Manuals - Energy Labels - High Resolution Photos

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …