Consoles – V6 series – Excellent performance, absolute comfort, and energy savings!

  • Excellent cooling and heating performance thanks to the Double Air Outlet
  • Scheduling the operation of the air conditioner according to your needs
  • Absolute comfort in setting the air-conditioner from wherever you are
  • Ideal conditions where you want them thanks to the Follow Me Mode
  • ECO Function for energy and cost savings

Become an Inventor Partner

Inventor air conditioners present the innovative air-conditioning unit management "HOTEL MENU". The HOTEL MENU is a set of features specifically designed to help better and more economical operation of air conditioners installed in hotel units.

The centralized multi-functional device can control up to 64 indoor units within a maximum connection length of 1200m. Control your air conditioner, set the temperature you want and select the mode you desire. Ideal for hotel & business units. *Refers to the units of 24.000~60.000btu/h

The variety of options provided by the pre-installed ON/OFF contact gives you the flexibility you need to manage your air conditioners, while saving time and energy. Install Door Switch or remote switches to turn units on or off easily and instantly. *Refers to the units of 24.000~60.000btu/h

The iClean function ensures the best air quality in your space, removing accumulated dust, mold and bacteria from inside the unit.

The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!

Prevent potential weather damages in places that are not heated and pose risks during the winter. Enable the 8°C function and the air conditioner only heats the room as needed while maintaining a stable room temperature of 8°C.

8°C Heating

With the On / Off switch, you can choose whether you want the fan to continue operating after the unit is turned off or stop.

Take the whole control of you unit! Thanks to the error code that will appear if an error occurs, you can always be safe and sure for the appropriate and most efficient operation of your air conditioner.

Error Alarm Port

With the GEAR function you achieve great energy savings, limiting the maximum consumption of the unit. You can adjust the performance in two stages, at 75% of maximum efficiency and 50%. Take care of the right temperature in your space, reducing operating costs.

Set the unit to start and stop automatically in a 24h period.

24-hour Timer
  • MODEL LV6LI-12WiFiR
  • Cooling Capacity 12.000 Btu / h
  • Cooling Capacity 3.52 kWatt
  • Heating Capacity 13.000 Btu / h
  • Heating Capacity 3.81 kWatt
  • Voltage / Frequency / Phase 220-240 / 50 / 1 V / Hz / Ph
  • Current Input - Cooling 4.5 A
  • Current Input - Heating 4.4 A
  • Power Input - Cooling 1.00 kW
  • Power Input - Heating 0.98 kW
  • Air Flow Volume (High / Medium / Low) 512/480/370 m³ / h
  • Noise Level (Silent / Low / Medium / High) 21/27/34/37 dB(A)
  • Sound Power Level 54 dB(A)
  • Dimensions (WxDxH) 794x206x621 mm
  • Net Weight 14.9 kg
  • Liquid Line - Gas Line 1 / 4” - 3 / 8”
  • MODEL LV6LI-18WiFiR
  • Cooling Capacity 17.000 Btu / h
  • Cooling Capacity 4.98 kWatt
  • Heating Capacity 18.000 Btu / h
  • Heating Capacity 5.28 kWatt
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input - Cooling 6.7 A
  • Current Input - Heating 6.4 A
  • Power Input - Cooling 1.50 kW
  • Power Input - Heating 1.42 kW
  • Air Flow Volume (High / Medium / Low) 560/480/400 m³ / h
  • Noise Level (Silent / Low / Medium / High) 24/32/38/41 dB(A)
  • Sound Power Level 55 dB(A)
  • Dimensions (WxDxH) 794x206x621 mm
  • Net Weight 14.9 kg
  • Liquid Line - Gas Line 1 / 4” - 1 / 2”

This feature refers to the reduced noise emissions in order to achieve a pleasant and comfortable unit operation. The special design of the indoor unit offers excellent performance at the lowest noise level, so that to enjoy ideal conditions of absolute silence.

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Take advantage of the 4 choices to adjust the indoor unit’s fan speed and benefit from the Filter Cleaning Reminder mode, the Louver Position Memory, the Temperature Compensation sensor and the Higher/ Lower Temperature settings to create the ideal conditions in your place.

Enjoy the flexibility offered by the Delay function, postponing the activation of the weekly schedule for up to 3 hours. Change your device settings for a specific day without changing your weekly schedule settings.

Ensure the operation of your appliance in cooling or heating without interference. With the locking feature, the operation of the air conditioner cannot be changed, avoiding incorrect settings, and offering a more correct and economical operation. Ideal for workplaces or hotel rooms.

Turn off the ability to use the wireless controller to adjust your air conditioner to ensure central control of the device from a single point. Suitable for business premises and hotels.

The perceived temperature by the indoor unit sensor may vary from the real temperature of the room, due to the position of the unit. Thanks to this function you can minimize the difference and achieve better conditions in your place.

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation.

The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.

Excellent heating performance even at the most demaning regions with low temperature levels. Ensure the prefered temperature conditions, even at -15°C and enjoy ideal conditions in your place.

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

Media Library for Consoles Multi Split units

User, Installation and Remote Controller Manuals - Energy Labels - High Resolution Photos - Technical Specifications & Features

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …