Comfort series with Ultraviolet Type C Technology & Ionizer, Motion Sensor & 56°C Sterilization!

  • Effective protection against germs, bacteria and viruses thanks to the Ultraviolet Type C Technology & Ionizer function
  • Ideal temperature and energy saving with the Motion Sensor
  • Excellent atmosphere of perfect silence in your place
  • Impeccable air quality thanks to the efficient cleaning of the unit’s interior with the 56°C Sterilization
  • Control and operation of the air conditioner through the Inventor Control application

Become an Inventor Partner

Ensure even distribution of air in all directions and cover even the most difficult parts of the room. The design of the series of air conditioners allows both horizontal and vertical movement of the blinds. Carefree & enjoy absolute comfort in every part of your home.

Meet your needs effectively, thanks to the special design for air distribution. Choose to diffuse air to the ceiling of the room for cooling mode to cool down quickly, avoiding exposure to cold air or to the floor in operation mode. heating, offering a warm atmosphere quickly. Enjoy ideal conditions in all seasons.

The technological superiority of the series guarantees excellent performances with the lowest operating costs. Take advantage of the highest energy class A+++ of Inventor air conditioners and create the perfect atmosphere exactly as you dream. At the same time save money while also taking care of the energy footprint by choosing an air conditioner with lower energy consumption.

A+++ Energy Class

The chassis heating belt located on the bottom of the outdoor unit prevents the ice formation and guarantees the proper operation of you air conditioner, even at low temperatures, or under the most difficult weather conditions. This advanced feature is specially designed for installations at northern regions where the temperature often falls below 0°C, since it will maintain the high-performance of your air-conditioner offering cost savings and a comfortable and warm atmosphere during winter.

Avoid possible weather disasters in places that are not heated during the winter, in the most economical way. Turn on the 10°C function and the air conditioner will heat the room as needed, keeping the temperature constant at 10°C. Protect the items in your space and ensure low consumption with maximum energy savings during the winter.

It eliminates unwanted moisture in the indoor unit during cooling mode operation. After turning off the air conditioner, the indoor unit’s fan will keep running for a while in order to dry the indoor unit.

Powerful Self-Cleaning

The outdoor unit’s special design produces an efficient and effective heating operation even at -20°C.

The outdoor unit’s special design produces an efficient and effective cooling operation even at -20°C.

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

Sleep Mode
  • MFVI-09WFI / MFVO-09
  • Cooling Capacity 8.870 (2.730-10.920) Btu / h
  • Cooling Capacity Range 2.6 (0.8-3.2) kWatt
  • Heating Capacity 10.920 (2.730-14.330) Btu / h
  • Heating Capacity 3.2 (0.8-4.2) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 2.6 kW
  • Energy Class A+++
  • SEER 8.5
  • Energy Consumption 107 kWh / year
  • Heating Middle Zone
  • Pdesign 2.4 kW
  • Energy Class A++
  • SCOP 4.6
  • Energy Consumption 731 kWh / year
  • Heating Warm Zone
  • Pdesign 2.3 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 631 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 2.9 (0.9-5.5) Α
  • Current Input Heating 3.6 (1.3-6.8) Α
  • Power Input Cooling 0.60 (0.2-1.2) kW
  • Power Input Heating 0.80 (0.3-1.5) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    650/600/500/350/250 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 16/25/32/38 db(A)
  • Noise Level Outdoor Unit 47 db(A)
  • Sound Power Level Indoor Unit 53 db(A)
  • Sound Power Level Outdoor Unit 59 db(A)
  • Dehumidifying Volume 1.2 L/h
  • Dehumidifying Volume 28.8 L/day
  • Compressor Type Panasonic
  • Liquid Line / Gas Line 1 / 4” | 3 / 8”
  • Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    856/197/300 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800/275/553 mm
  • Net Weight Indoor / Outdoor 9.5/27.6 kg
  • Refrigerant / Charge R32 / 630 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C
  • MFVI-12WFI / MFVO-12
  • Cooling Capacity 11.940 (3.410-13.650) Btu / h
  • Cooling Capacity Range 3.5 (1.0-4.0) kWatt
  • Heating Capacity 14.330 (3.410-17.740) Btu / h
  • Heating Capacity 4.2 (1.0-5.2) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A+++
  • SEER 8.5
  • Energy Consumption 144 kWh / year
  • Heating Middle Zone
  • Pdesign 2.8 kW
  • Energy Class A++
  • SCOP 4.6
  • Energy Consumption 854 kWh / year
  • Heating Warm Zone
  • Pdesign 2.8 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 768 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 3.9 (1.4-6.7) Α
  • Current Input Heating 5.0 (2.3-7.2) Α
  • Power Input Cooling 0.88 (0.3-1.5) kW
  • Power Input Heating 1.10 (0.5-1.6) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    700/650/550/400/300 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 17/26/33/39 db(A)
  • Noise Level Outdoor Unit 48 db(A)
  • Sound Power Level Indoor Unit 55 db(A)
  • Sound Power Level Outdoor Unit 61 db(A)
  • Dehumidifying Volume 1.6 L/h
  • Dehumidifying Volume 38.4 L/day
  • Compressor Type Hitachi
  • Liquid Line / Gas Line 1 / 4” | 3 / 8”
  • Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    856/197/300 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800/275/553 mm
  • Net Weight Indoor / Outdoor 9.5/30.0 kg
  • Refrigerant / Charge R32 / 780 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C
  • MFVI32-18WFI/MFVO32-18
  • Cooling Capacity 17.740 (4.770-20.470) Btu / h
  • Cooling Capacity Range 5.2 (1.4-6.0) kWatt
  • Heating Capacity 20.470 (4.770-23.540) Btu / h
  • Heating Capacity 6.0 (1.4-6.9) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 5.2 kW
  • Energy Class A++
  • SEER 7.2
  • Energy Consumption 253 kWh / year
  • Heating Middle Zone
  • Pdesign 4.6 kW
  • Energy Class A++
  • SCOP 4.6
  • Energy Consumption 1.401 kWh / year
  • Heating Warm Zone
  • Pdesign 4.8 kW
  • Energy Class A+++
  • SCOP 5.6
  • Energy Consumption 1.190 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 6.2 (1.8-8.9) Α
  • Current Input Heating 6.7 (2.3-10.9) Α
  • Power Input Cooling 1.40 (0.5-2.0) kW
  • Power Input Heating 1.50 (0.5-2.4) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    1.050/900/750/650/550 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 28/37/41/45 db(A)
  • Noise Level Outdoor Unit 51 db(A)
  • Sound Power Level Indoor Unit 57 db(A)
  • Sound Power Level Outdoor Unit 63 db(A)
  • Dehumidifying Volume 2.0 L/h
  • Dehumidifying Volume 48.0 L/day
  • Compressor Type Mitsubishi
  • Liquid Line / Gas Line 1 / 4” | 1 / 2”
  • Power Supply Wire Outdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    999/225/323 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    820/338/614 mm
  • Net Weight Indoor / Outdoor 12.0/37.8 kg
  • Refrigerant / Charge R32 / 950 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C
  • MFVI32-24WFI/MFVO32-24
  • Cooling Capacity 23.890 (7.510-25.600) Btu / h
  • Cooling Capacity Range 7.0 (2.2-7.5) kWatt
  • Heating Capacity 27.300 (8.190-29.000) Btu / h
  • Heating Capacity 8.0 (2.4-8.5) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 7.0 kW
  • Energy Class A++
  • SEER 7.0
  • Energy Consumption 345 kWh / year
  • Heating Middle Zone
  • Pdesign 5.6 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1.959 kWh / year
  • Heating Warm Zone
  • Pdesign 5.2 kW
  • Energy Class A+++
  • SCOP 5.4
  • Energy Consumption 1.357 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 9.6 (3.2-11.2) Α
  • Current Input Heating 9.6 (3.2-13.0) Α
  • Power Input Cooling 2.17 (0.7-2.5) kW
  • Power Input Heating 2.16 (0.7-2.9) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    1.250/1.100/950/850/700 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 33/37/43/47 db(A)
  • Noise Level Outdoor Unit 57 db(A)
  • Sound Power Level Indoor Unit 60 db(A)
  • Sound Power Level Outdoor Unit 70 db(A)
  • Dehumidifying Volume 2.8 L/h
  • Dehumidifying Volume 67.2 L/day
  • Compressor Type Mitsubishi
  • Liquid Line / Gas Line 3 / 8” | 5 / 8”
  • Power Supply Wire Outdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.115/235/343 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    890/353/697 mm
  • Net Weight Indoor / Outdoor 15.2/49.0 kg
  • Refrigerant / Charge R32 / 1.300 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Horizontal louver will automatically move to the same position as you set last time when the unit turned on.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

The exquisite filter optimizes the filtering effect by 40%.

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

Thanks to the support base that extends to the back of the air conditioner, the technician ensures up to 48% more space during installation to complete the work comfortably and faster.

The technician now needs less time to install or maintain the device. The lid is easily removed from the bottom of the air conditioner so that the coolant can easily make the necessary connections without the use of tools.

Removing the motor and the board is now an easy process as no disassembly of the other parts of the air conditioner is required. This saves 80% less time on air conditioner maintenance.

The device has a flexible clip that facilitates its installation, while offering convenience during the service process.

Media Library for Comfort air conditioners

User, Wi-Fi, Remote Controller & Installation Manuals - Energy Labels - High Resolution Photos - Technical Specifications & Features

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …