Features
Benefits
Auto Swing Louver
Distributes cool/warm air to maximum area by moving horizontal flaps automatically.
Golden Fin
The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!
Powerful Self-Cleaning
It eliminates unwanted moisture in the indoor unit during cooling mode operation. After turning off the air conditioner, the indoor unit’s fan will keep running for a while in order to dry the indoor unit.

ECO mode
With the new ECO mode on your remote controller, you can set your air conditioner to operate at the lowest cost, achieving maximum energy savings & enjoying the greatest conditions in your place.
Low Ambient Heating at -20°C
The outdoor unit’s special design produces an efficient and effective heating operation even at -20°C.
Turbo Mode
This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Louver Position Memory
Horizontal louver will automatically move to the same position as you set last time when the unit turned on
24-hour Timer
Set the unit to start and stop automatically in a 24h period.

Sleep Mode
With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

Favourite Settings Save Function
Set your favourite program as default according to the season and the weather and make your daily life easier! Choose your favourite mode, fan speed, temperature or louver movement and enjoy the atmosphere that you prefer when you get home, simply by touching a button.
Technical Specifications
- PFUVI-09WFI / PFUVO-09
- Cooling Capacity 9.042 (2.047-10.577) Btu / h
- Cooling Capacity Range 2.65 (0.6-3.1) kWatt
- Heating Capacity 9.212 (2.730-11.601) Btu / h
- Heating Capacity 2.7 (0.8-3.4) kWatt
-
Seasonal Efficiency
(In accordance to ΕΝ14825) - Cooling
- Pdesign 2.7 kW
- Energy Class A++
- SEER 6.5
- Energy Consumption 145 kWh / year
- Heating Middle Zone
- Pdesign 2.3 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 805 kWh / year
- Heating Warm Zone
- Pdesign 2.3 kW
- Energy Class A+++
- SCOP 5.2
- Energy Consumption 619 kWh / year
- Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
- Current Input Cooling 3.6 (0.9-6.9) Α
- Current Input Heating 3.2 (1.3-6.9) Α
- Power Input Cooling 0.81 (0.1-1.6) kW
- Power Input Heating 0.72 (0.3-1.5) W
- Air Flow Volume 600 m³ / h
- Noise Level Indoor Unit (Silent / Low / Med / Hi) 25/31/37/44 db(A)
- Sound Power Level Outdoor Unit 51 db(A)
- Sound Power Level Indoor Unit 53 db(A)
- Sound Power Level Outdoor Unit 61 db(A)
- Dehumidifying Volume 0.9 L/h
- Dehumidifying Volume 21.6 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” / 3 / 8”
- Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
- Signal Wires 5 × 1.0 No x mm²
-
Dimensions
Indoor Unit
(WxDxH) 792x201x292 mm -
Dimensions
Outdoor Unit
(WxDxH) 649x278x456 mm - Net Weight Indoor / Outdoor 8.5 / 18 kg
- Refrigerant / Charge R32 / 550 g
- Operation Temperature Range Outdoor Unit Cooling 16~49 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
- PFUVI-12WFI / PFUVO-12
- Cooling Capacity 11.942 (2.730-13.989) Btu / h
- Cooling Capacity Range 3.5 (0.8-4.1) kWatt
- Heating Capacity 12.966 (3.412-14.330) Btu / h
- Heating Capacity 3.8 (1.0-4.2) kWatt
-
Seasonal Efficiency
(In accordance to ΕΝ14825) - Cooling
- Pdesign 3.5 kW
- Energy Class A++
- SEER 6.1
- Energy Consumption 198 kWh / year
- Heating Middle Zone
- Pdesign 2.7 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 938 kWh / year
- Heating Warm Zone
- Pdesign 3.4 kW
- Energy Class A+++
- SCOP 5.2
- Energy Consumption 914 kWh / year
- Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
- Current Input Cooling 5.6 (0.7-7.8) Α
- Current Input Heating 4.9 (1.5-8.0) Α
- Power Input Cooling 1.18 (0.1-1.6) kW
- Power Input Heating 1.1 (0.3-1.6) W
- Air Flow Volume 600 m³ / h
- Noise Level Indoor Unit (Silent / Low / Med / Hi) 26/33/39/44 db(A)
- Sound Power Level Outdoor Unit 52 db(A)
- Sound Power Level Indoor Unit 53 db(A)
- Sound Power Level Outdoor Unit 62 db(A)
- Dehumidifying Volume 1.0 L/h
- Dehumidifying Volume 24.0 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” / 3 / 8”
- Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
- Signal Wires 5 × 1.0 No x mm²
-
Dimensions
Indoor Unit
(WxDxH) 792x201x292 mm -
Dimensions
Outdoor Unit
(WxDxH) 705x309x530 mm - Net Weight Indoor / Outdoor 8.5 / 22.5 kg
- Refrigerant / Charge R32 / 560 g
- Operation Temperature Range Outdoor Unit Cooling 16~49 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
- PFUVI-18WFI / PFUVO-18
- Cooling Capacity 18.084 (4.436-19.448) Btu / h
- Cooling Capacity Range 5.3 (1.3-5.7) kWatt
- Heating Capacity 18.084 (4.436-18.766) Btu / h
- Heating Capacity 5.3 (1.3-5.5) kWatt
-
Seasonal Efficiency
(In accordance to ΕΝ14825) - Cooling
- Pdesign 5.3 kW
- Energy Class A++
- SEER 6.5
- Energy Consumption 285 kWh / year
- Heating Middle Zone
- Pdesign 3.9 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 1.365 kWh / year
- Heating Warm Zone
- Pdesign 4.3 kW
- Energy Class A+++
- SCOP 5.2
- Energy Consumption 1.158 kWh / year
- Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
- Current Input Cooling 7.8 (2.2-9.3) Α
- Current Input Heating 6.5 (2.0-8.0) Α
- Power Input Cooling 1.65 (0.29-2.1) kW
- Power Input Heating 1.47 (0.25-1.8) W
- Air Flow Volume 900 m³ / h
- Noise Level Indoor Unit (Silent / Low / Med / Hi) 30/36/41/47 db(A)
- Sound Power Level Outdoor Unit 56 db(A)
- Sound Power Level Indoor Unit 58 db(A)
- Sound Power Level Outdoor Unit 63 db(A)
- Dehumidifying Volume 1.6 L/h
- Dehumidifying Volume 38.4 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” / 1 / 2”
- Power Supply Wire Outdoor 3 x 2.5 / 16 No x mm² / A
- Signal Wires 5 × 1.5 No x mm²
-
Dimensions
Indoor Unit
(WxDxH) 940x224x316 mm -
Dimensions
Outdoor Unit
(WxDxH) 785x353x555 mm - Net Weight Indoor / Outdoor 10 / 28 kg
- Refrigerant / Charge R32 / 1.030 g
- Operation Temperature Range Outdoor Unit Cooling 16~49 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
- PFUVI-24WFI / PFUVO-24
- Cooling Capacity 24.566 (6.142-25.248) Btu / h
- Cooling Capacity Range 7.2 (1.8-7.4) kWatt
- Heating Capacity 24.566 (6.142-27.296) Btu / h
- Heating Capacity 7.2 (1.8-7.4) kWatt
-
Seasonal Efficiency
(In accordance to ΕΝ14825) - Cooling
- Pdesign 6.7 kW
- Energy Class A++
- SEER 6.5
- Energy Consumption 359 kWh / year
- Heating Middle Zone
- Pdesign 5.7 kW
- Energy Class A+
- SCOP 4.0
- Energy Consumption 1.950 kWh / year
- Heating Warm Zone
- Pdesign 7.0 kW
- Energy Class A+++
- SCOP 5.2
- Energy Consumption 1.589 kWh / year
- Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
- Current Input Cooling 10.0 (1.0-12.0) Α
- Current Input Heating 9.5 (1.0-11.0) Α
- Power Input Cooling 2.2 (0.23-2.76) kW
- Power Input Heating 2.2 (0.23-2.53) W
- Air Flow Volume 1.300 m³ / h
- Noise Level Indoor Unit (Silent / Low / Med / Hi) 31/37/43/48 db(A)
- Sound Power Level Outdoor Unit 58 db(A)
- Sound Power Level Indoor Unit 63 db(A)
- Sound Power Level Outdoor Unit 66 db(A)
- Dehumidifying Volume 2.5 L/h
- Dehumidifying Volume 60.0 L/day
- Compressor Type ROTARY
- Liquid Line / Gas Line 1 / 4” / 5 / 8”
- Power Supply Wire Outdoor 3 x 2.5 / 16 No x mm² / A
- Signal Wires 5 × 1.5 No x mm²
-
Dimensions
Indoor Unit
(WxDxH) 1.132x232x330 mm -
Dimensions
Outdoor Unit
(WxDxH) 900x388x700 mm - Net Weight Indoor / Outdoor 14 / 39 kg
- Refrigerant / Charge R32 / 1.300 g
- Operation Temperature Range Outdoor Unit Cooling 16~49 °C
- Operation Temperature Range Outdoor Unit Heating -20~30 °C
More
Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.
All DC Inverter
The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.
Refrigerant Leakage Detect
Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
R32 ECO Refrigerant
The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.
Media Library for Professional (PFUV) air conditioners
User& Installation, Remote Controller & Wi-Fi Manuals - Energy Labels - High Resolution Photos - Technical Specifications
Find more
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …