A+++ & Wi-Fi Ready for energy saving. High Performance Omnia Plus series with great price

  • Comfort & Energy Savings thanks to smart Wi-Fi control
  • Energy class A+++ for ideal operation and even greater energy savings
  • High Density Air Dust Filter for 40% more dust absorption
  • Superpower Ionizer for clean and healthy atmosphere in your place
  • Ideal hygiene in your place thanks to Triple Action Filter & HEPA Filter

Become an Inventor Partner

  • O2MVI - 09WiFiR / O2MVO - 09
  • Cooling Capacity 9.000 Btu / h
  • Heating Capacity 10.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (3.500-11.000) Btu / h
  • Cooling Capacity Range 2.64 (1.02-3.22) kWatt
  • Heating Capacity (2.800-11.500) Btu / h
  • Heating Capacity 2.93 (0.82-3.37) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 2.6 kW
  • Energy Class A++
  • SEER 6.2
  • Energy Consumption 147 kWh / year
  • Heating Middle Zone
  • Pdesign 2.2 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 770 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 2.8 kW
  • SCOP 5.1
  • Energy Consumption 769 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 3.8 (0.4 - 5.4) Α
  • Current Input Heating 3.9 (0.5 - 5.2) Α
  • Power Input Cooling 879 (100 - 1.240) W
  • Power Input Heating 887 (120 - 1.200) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 22.5 / 27 / 34 / 40 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    420 / 320 / 270 m³ / h
  • Sound Power Level Outdoor Unit 55.5 db(A)
  • Sound Power Level Indoor Unit 52 db(A)
  • Sound Power Level Outdoor Unit 60 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4" / 3/8"
  • Power Supply Wire OUtdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    715 × 194 × 285 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    770 × 300 × 555 mm
  • Net Weight Indoor / Outdoor 6.8 / 25.2 kg
  • Refrigerant R410A / 800g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C
  • O2MVI - 12WiFiR / O2MVO - 12
  • Cooling Capacity 12.000 Btu / h
  • Heating Capacity 13.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (3.700-14.000) Btu / h
  • Cooling Capacity Range 3.52 (1.08-4.10) kWatt
  • Heating Capacity (3.000-14.400) Btu / h
  • Heating Capacity 3.81 (0.87-4.22) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A++
  • SEER 6.1
  • Energy Consumption 201 kWh / year
  • Heating Middle Zone
  • Pdesign 2.3 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 805 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 2.9 kW
  • SCOP 5.1
  • Energy Consumption 796 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 5.5 (0.4 - 6.9) Α
  • Current Input Heating 5.0 (0.6 - 6.6) Α
  • Power Input Cooling 1.256(100-1.580) W
  • Power Input Heating 1.154(130-1.510) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 23 / 28 / 36 / 41 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    570 / 470/ 370 m³ / h
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 53 db(A)
  • Sound Power Level Outdoor Unit 59 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4" / 3/8"
  • Power Supply Wire OUtdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    805 × 194 × 285 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    770 × 300 × 555 mm
  • Net Weight Indoor / Outdoor 7.2 / 25.5 kg
  • Refrigerant R410A / 800g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C
  • O2MVI - 18WiFiR / O2MVO - 18
  • Cooling Capacity 18.000 Btu / h
  • Heating Capacity 19.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (6.200-20.900) Btu / h
  • Cooling Capacity Range 5.28 (1.81-6.13) kWatt
  • Heating Capacity (4.700-23.000) Btu / h
  • Heating Capacity 5.57 (1.37-6.74) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 5.3 kW
  • Energy Class A++
  • SEER 6.4
  • Energy Consumption 290 kWh / year
  • Heating Middle Zone
  • Pdesign 4.2 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1,470 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 4.4 kW
  • SCOP 5.1
  • Energy Consumption 1,208 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 7.1 (0.6 - 10.3) Α
  • Current Input Heating 6.7 (0.9 - 10.5) Α
  • Power Input Cooling 1.633(140-2.360) W
  • Power Input Heating 1.542(200-2.410) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 25 / 35 / 40 / 47 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    840 / 680 / 540 m³ / h
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 56 db(A)
  • Sound Power Level Outdoor Unit 63 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4" / 1/2"
  • Power Supply Wire OUtdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    957 × 213 × 302 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800 × 333 × 554 mm
  • Net Weight Indoor / Outdoor 9.5 / 37.8 kg
  • Refrigerant R410A / 1.480g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C
  • O2MVI - 24WiFiR / O2MVO - 24
  • Cooling Capacity 24.000 Btu / h
  • Heating Capacity 25.000 Btu / h
  • Energy Class A+++
  • Cooling Capacity Range (9.100-26.900) Btu / h
  • Cooling Capacity Range 7.03 (2.66-7.88) kWatt
  • Heating Capacity (5.500-30.000) Btu / h
  • Heating Capacity 7.33 (1.61-8.79) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 7.0 kW
  • Energy Class A++
  • SEER 6.1
  • Energy Consumption 402 kWh / year
  • Heating Middle Zone
  • Pdesign 5.4 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1,890 kWh / year
  • Heating Warm Zone
  • Energy Class A+++
  • Pdesign 6.3 kW
  • SCOP 5.1
  • Energy Consumption 1,729 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 11.7 (1.0 - 13.2) Α
  • Current Input Heating 11.1 (1.1 - 13.7) Α
  • Power Input Cooling 2.684(240-3.030) W
  • Power Input Heating 2.549(260-3.140) W
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 27 / 34 / 39 / 45 db(A)
  • Air Flow Volume
    (Hi / Med / Low)
    980 / 800 / 640 m³ / h
  • Sound Power Level Outdoor Unit 60 db(A)
  • Sound Power Level Indoor Unit 59 db(A)
  • Sound Power Level Outdoor Unit 65 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 3 / 8" / 5/8"
  • Power Supply Wire OUtdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 5 x 15 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.040×220×327 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    845 × 363 × 702 mm
  • Net Weight Indoor / Outdoor 11.9 / 48.4 kg
  • Refrigerant R410A / 1.850g
  • Operation Temperature Range Outdoor Unit Cooling -15 - 50 °C
  • Operation Temperature Range Outdoor Unit Heating -15 - 30 °C

Want to turn off the AC beep and display? By pressing the mute operation, Inventor AC helps to give you a quiet and comfortable night.

Mute Mode

It eliminates unwanted moisture in the indoor unit during cooling mode operation. After turning off the air conditioner, the indoor unit’s fan will keep running for a while in order to dry the indoor unit.

Powerful Self-Cleaning

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

Horizontal louver will automatically move to the same position as you set last time when the unit turned on

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected

The temperature detected by the indoor unit temperature probe will often be different from the actual ground temperature, due to the indoor units being installed at different heights.

Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.

Power consumption from 1.0W in StandBy mode for higher energy savings.

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation

When temperature sensor error happens, the air conditioner will display error code and stop immediately, while AC displays error and continues running in a proper status, to avoid the case that AC is in urgent need.

Distributes cool/warm air to maximum area by moving horizontal flaps automatically.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

Set the unit to start and stop automatically in a 24h period.

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Up to 12 grades indoor fan speeds, ensure more accurate control and brings more comfortable air flow.

Due to the DC fan motor, outdoor fan speeds increase from 2 grades to 5 grades, more comfortable and reinforces energy saving.

Media Library for Omnia air conditioners

User, Remote Control & Installation Manuals - Energy Labels - Pdesign Test Report - High Resolution Photos

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …