Aria air conditioning series with HEPA Filter, Ionizer & A+++ Energy Class!

  • Clean & healthy environment thanks to the Sterilization HEPA Filter
  • Pleasant atmosphere and protection against viruses with the integrated Ionizer
  • Maximum energy savings thanks to A+++ Energy Class
  • Ideal environment of low noise level thanks to the Ultra Silence Mode of the unit
  • Ensure ultimate comfort levels from controlling every function via smartphone or tablet
  • Ultimate adjustment to your needs with the Follow Me function
  • AR3VI32-09WF/ AR3VO32-09
  • Cooling Capacity 9.000 Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 20/23/31/39 db(A)
  • Cooling Capacity Range (1.03-3.19) kWatt
  • Heating Capacity 10.000 Btu / h
  • Heating Capacity (0.88-3.66) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 2.6 kW
  • Energy Class A++
  • SEER 7.1
  • Energy Consumption 128 kWh / year
  • Heating Middle Zone
  • Pdesign 2.6 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 910 kWh / year
  • Heating Warm Zone
  • Pdesign 3.0 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 824 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 3.05 (0.3-5.3) Α
  • Current Input Heating 3.17 (0.6-5.7) Α
  • Power Input Cooling 703 (70-1.230) W
  • Power Input Heating 731 (140-1.310) W
  • Air Flow Volume
    (High/Medium/Low)
    416/309/230 m³ / h
  • Sound Power Level Outdoor Unit 55.5 db(A)
  • Sound Power Level Indoor Unit 54 db(A)
  • Sound Power Level Outdoor Unit 59 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 3 / 8”
  • Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 5 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    722x187x290 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    770x300x555 mm
  • Net Weight Indoor / Outdoor 7.3/27.2 kg
  • Refrigerant / Charge R32/0.7 kg
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C
  • AR3VI32-12WF/ AR3VO32-12
  • Cooling Capacity 12.000 Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 21/22/32/38 db(A)
  • Cooling Capacity Range (0.82-4.16) kWatt
  • Heating Capacity 13.000 Btu / h
  • Heating Capacity (0.85-4.78) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A++
  • SEER 7.0
  • Energy Consumption 175 kWh / year
  • Heating Middle Zone
  • Pdesign 2.7 kW
  • Energy Class A+
  • SCOP 4.1
  • Energy Consumption 922 kWh / year
  • Heating Warm Zone
  • Pdesign 3.3 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 906 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 4.74 (0.2-6.9) Α
  • Current Input Heating 4.47 (0.6-7.4) Α
  • Power Input Cooling 1.089 (50-1.600) W
  • Power Input Heating 1.050 (130-1.710) W
  • Air Flow Volume
    (High/Medium/Low)
    515/459/294 m³ / h
  • Sound Power Level Outdoor Unit 54 db(A)
  • Sound Power Level Indoor Unit 56 db(A)
  • Sound Power Level Outdoor Unit 60 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 3 / 8”
  • Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 5 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    802x189x297 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    770x300x555 mm
  • Net Weight Indoor / Outdoor 8.2/27.0 kg
  • Refrigerant / Charge R32/0.8 kg
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C
  • AR3VI32-18WF/ AR3VO32-18
  • Cooling Capacity 18.000 Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 20/28/35/41 db(A)
  • Cooling Capacity Range (1.85-6.15) kWatt
  • Heating Capacity 19.000 Btu / h
  • Heating Capacity (1.38-6.80) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 5.3 kW
  • Energy Class A++
  • SEER 6.4
  • Energy Consumption 290 kWh / year
  • Heating Middle Zone
  • Pdesign 3.9 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1.365 kWh / year
  • Heating Warm Zone
  • Pdesign 4.5 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 1.235 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 6.7 (0.7-10.3) Α
  • Current Input Heating 6.7 (0.9-11.5) Α
  • Power Input Cooling 1.547 (120-2.380) W
  • Power Input Heating 1.500 (220-2.430) W
  • Air Flow Volume
    (High/Medium/Low)
    750/501/417 m³ / h
  • Sound Power Level Outdoor Unit 57 db(A)
  • Sound Power Level Indoor Unit 58 db(A)
  • Sound Power Level Outdoor Unit 64 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 1 / 2”
  • Power Supply Wire Outdoor 3 × 2.5 / 16 No x mm² / A
  • Signal Wires 5 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    965x215x319 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800x333x554 mm
  • Net Weight Indoor / Outdoor 10.8/37.0 kg
  • Refrigerant / Charge R32/1.25 kg
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C
  • AR3VI32-24WF/ AR3VO32-24
  • Cooling Capacity 24.000 Btu / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 26/30/40/46 db(A)
  • Cooling Capacity Range (2.58-8.44) kWatt
  • Heating Capacity 26.000 Btu / h
  • Heating Capacity (1.52-9.44) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14.825)
  • Cooling
  • Pdesign 7.2 kW
  • Energy Class A++
  • SEER 6.4
  • Energy Consumption 394 kWh / year
  • Heating Middle Zone
  • Pdesign 5.1 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1.785 kWh / year
  • Heating Warm Zone
  • Pdesign 6.3 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 1.729 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 10.4 (1.0-14.1) Α
  • Current Input Heating 9.46 (1.4-14.4) Α
  • Power Input Cooling 2.402 (230-3.350) W
  • Power Input Heating 2.177 (230-3.370) W
  • Air Flow Volume
    (High/Medium/Low)
    1.020/830/640 m³ / h
  • Sound Power Level Outdoor Unit 60 db(A)
  • Sound Power Level Indoor Unit 62 db(A)
  • Sound Power Level Outdoor Unit 66 db(A)
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 3 / 8” / 5 / 8”
  • Power Supply Wire Outdoor 3 × 2.5 / 16 No x mm² / A
  • Signal Wires 5 × 2.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.080x226x335 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    845x363x702 mm
  • Net Weight Indoor / Outdoor 12.9/50.0 kg
  • Refrigerant / Charge R32/1.6 kg
  • Operation Temperature Range Outdoor Unit Cooling -15~50 °C
  • Operation Temperature Range Outdoor Unit Heating -15~30 °C

Inventor air conditioners present the innovative air-conditioning unit management "HOTEL MENU". The HOTEL MENU is a set of features specifically designed to help better and more economical operation of air conditioners installed in hotel units.

Triple Action Filter with Vitamin C, Silver Ion and Cold Catalyst protects your skin and improves the air

Triple Action Filter

It eliminates unwanted moisture in the indoor unit during cooling mode operation. After turning off the air conditioner, the indoor unit’s fan will keep running for a while in order to dry the indoor unit.

Powerful Self-Cleaning

The renewed design creates uniform air distribution in all dimensions. The vent swings not only move horizontally but vertically as well dispersing the air smoothly even in the most difficult spots.

4 Way Air Flow

The exquisite filter optimizes the filtering effect by 40%.

High Density Air Dust Filter

Prevent potential weather damages in places that are not heated and pose risks during the winter. Enable the 8°C function and the air conditioner only heats the room as needed while maintaining a stable room temperature of 8°C.

8°C Heating

The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!

The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.

Low Ambient Cooling

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

Sleep Mode

Set the unit to start and stop automatically in a 24h period.

24-hour Timer

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation

Power consumption from 1.0W in StandBy mode for higher energy savings.

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Want to turn off the AC beep and display? By pressing the mute operation, Inventor AC helps to give you a quiet and comfortable night.

Up to 12 grades indoor fan speeds, ensure more accurate control and brings more comfortable air flow.

Due to the DC fan motor, outdoor fan speeds increase from 2 grades to 5 grades, more comfortable and reinforces energy saving.

The perceived temperature by the indoor unit sensor may vary from the real temperature of the room, due to the position of the unit. Thanks to this function you can minimize the difference and achieve better conditions in your place.

Distributes cool/warm air to maximum area by moving horizontal flaps automatically.

Horizontal louver will automatically move to the same position as you set last time when the unit turned on

Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

When temperature sensor error happens, the air conditioner will display error code and stop immediately, while AC displays error and continues running in a proper status, to avoid the case that AC is in urgent need.

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

Power saving and improved heating efficiency by intelligent defrost. Intelligent Defrost is achieved only by sensors that they control the need and duration of defrost process.

Media Library for King air conditioners

User, Remote Controller, Wi-Fi & Installation Manuals - Energy Labels - High Resolution Photos - Technical Specifications

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …