Omnia Plus On/ Off Heat Pump R22

  • Optimal conditions thanks to Anti-Cold Air Function
  • 24-Hours Timer for more convenience and energy savings
  • Sleep mode for perfect sleeping conditions

Become an Inventor Partner

  • MODEL O1HMI - 09 / O1HMO - 09
  • Cooling Capacity 9.000 Btu / h
  • Cooling Capacity 2.64 kWatt
  • Heating Capacity 9.500 Btu / h
  • Heating Capacity 2.78 kWatt
  • EER 2.61 W / W
  • COP 2.81 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 4.4 A
  • Current Input-Heating 4.3
  • Power Input-Cooling 1.010 W
  • Power Input-Heating 990
  • Air Flow Volume (Hi / Med / Low) 457 / 405 / 351 m³ / h
  • Noise Level-Indoor Unit 30.6 / 35.7 / 39.6 (db(A))
  • Noise Level-Outdoor Unit 54.9
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4" / 3/8"
  • Dimensions -Indoor Unit WxDxH 715 × 194 × 285 mm
  • Dimensions - Outdoor Unit WxDxH 681 × 285 × 434
  • Net Weight Indoor / Outdoor 7.6 / 23.5 kg
  • Refrigerant R22 / 550g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 140 / 320
  • MODEL O1HMI - 12 / O1HMO - 12
  • Cooling Capacity 12.000 Btu / h
  • Cooling Capacity 3.52 kWatt
  • Heating Capacity 13.000 Btu / h
  • Heating Capacity 3.81 kWatt
  • EER 2.61 W / W
  • COP 3.26 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 5.8 A
  • Current Input-Heating 5.1
  • Power Input-Cooling 1.347 W
  • Power Input-Heating 1.168
  • Air Flow Volume (Hi / Med / Low) 574 / 447 / 350 m³ / h
  • Noise Level-Indoor Unit 32.2 / 37.8 /42.9 (db(A))
  • Noise Level-Outdoor Unit 55.1
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4" / 1/2"
  • Dimensions -Indoor Unit WxDxH 805 × 194 × 285 mm
  • Dimensions - Outdoor Unit WxDxH 770 × 300 × 555
  • Net Weight Indoor / Outdoor 8.5 / 28.9 kg
  • Refrigerant R22 / 880g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 104 / 240
  • MODEL O1HMI - 18 / O1HMO - 18
  • Cooling Capacity 17.000 Btu / h
  • Cooling Capacity 4.98 kWatt
  • Heating Capacity 18.000 Btu / h
  • Heating Capacity 5.28 kWatt
  • EER 2.61 W / W
  • COP 3.01 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 8.3 A
  • Current Input-Heating 7.6
  • Power Input-Cooling 1.908 W
  • Power Input-Heating 1.752
  • Air Flow Volume (Hi / Med / Low) 751 / 607 / 488 m³ / h
  • Noise Level-Indoor Unit 33.8 / 38.8 / 43.9 (db(A))
  • Noise Level-Outdoor Unit 58.2
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4" / 1/2"
  • Dimensions -Indoor Unit WxDxH 957 × 213 × 302 mm
  • Dimensions - Outdoor Unit WxDxH 770 × 300 × 555
  • Net Weight Indoor / Outdoor 10.6 / 35.7 kg
  • Refrigerant R22 / 1.250g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 90 / 208
  • MODEL O1HMI - 24 / O1HMO - 24
  • Cooling Capacity 22.000 Btu / h
  • Cooling Capacity 6.45 kWatt
  • Heating Capacity 23.000 Btu / h
  • Heating Capacity 6.74 kWatt
  • EER 2.61 W / W
  • COP 3.01 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 10.7 A
  • Current Input-Heating 9.7
  • Power Input-Cooling 2.470 W
  • Power Input-Heating 2.238
  • Air Flow Volume (Hi / Med / Low) 1.066 / 956 / 764 m³ / h
  • Noise Level-Indoor Unit 38.8 / 43.9 / 46.4 (db(A))
  • Noise Level-Outdoor Unit 58.8
  • Compressor Type ROTARY
  • Liquid line / Gas line 3 / 8" / 5/8"
  • Dimensions -Indoor Unit WxDxH 1.040×220×327 mm
  • Dimensions - Outdoor Unit WxDxH 845 × 363 × 702
  • Net Weight Indoor / Outdoor 13.4 / 47.9 kg
  • Refrigerant R22 / 1.700g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 66 / 154

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Turbo Mode

Set the unit to start and stop automatically in a 24h period.

24-hour Timer

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

Auto Error Diagnosis

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Auto Restart

After setting the desired temperature, the unit will automatically adjust its operation in order to keep stable the temperature you have set

Horizontal louver will automatically move to the same position as you set last time when the unit turned on

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected

Distributes cool/warm air to maximum area by moving horizontal flaps automatically.

Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.

All you need to know about