Features
Become an Inventor Partner
Specs
- MODEL O1CMI - 09 / O1CMO - 09
- Cooling Capacity 9.000 Btu / h
- Cooling Capacity 2.64 kWatt
- -
- Heating Capacity - kWatt
- EER 2.61 W / W
- COP - W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 4.4 A
- Current Input-Heating -
- Power Input-Cooling 1.010 W
- Power Input-Heating -
- Air Flow Volume (Hi / Med / Low) 457 / 405 / 351 m³ / h
- Noise Level-Indoor Unit 30.2/ 35.5 /39.2 (db(A))
- Noise Level-Outdoor Unit 52.3
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4" / 3/8"
- Dimensions -Indoor Unit WxDxH 715 × 194 × 285 mm
- Dimensions - Outdoor Unit WxDxH 681 × 285 × 434
- Net Weight Indoor / Outdoor 7.6 / 22.3 kg
- Refrigerant R22 / 450g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -
- Loading Quantities per 20’ / 40’HC 140 / 320
- MODEL O1CMI - 12 / O1CMO - 12
- Cooling Capacity 11.000 Btu / h
- Cooling Capacity 3.22 kWatt
- -
- Heating Capacity - kWatt
- EER 2.61 W / W
- COP - W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 2.8 A
- Current Input-Heating -
- Power Input-Cooling 1.235 W
- Power Input-Heating -
- Air Flow Volume (Hi / Med / Low) 538 / 427 / 340 m³ / h
- Noise Level-Indoor Unit 30.6 / 34.1 / 40.1 (db(A))
- Noise Level-Outdoor Unit 52.4
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4" / 3/8"
- Dimensions -Indoor Unit WxDxH 805 × 194 × 285 mm
- Dimensions - Outdoor Unit WxDxH 700 × 275 × 550
- Net Weight Indoor / Outdoor 8.0 / 25.3 kg
- Refrigerant R22 / 480g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -
- Loading Quantities per 20’ / 40’HC 115 / 270
- MODEL O1CMI - 18 / O1CMO - 18
- Cooling Capacity 17.000 Btu / h
- Cooling Capacity 4.98 kWatt
- -
- Heating Capacity - kWatt
- EER 2.61 W / W
- COP - W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 8.3 A
- Current Input-Heating -
- Power Input-Cooling 1.908 W
- Power Input-Heating -
- Air Flow Volume (Hi / Med / Low) 751 / 607 / 488 m³ / h
- Noise Level-Indoor Unit 35.1 / 38.8 / 44.3 (db(A))
- Noise Level-Outdoor Unit 56.8
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4" / 1/2"
- Dimensions -Indoor Unit WxDxH 957 × 213 × 302 mm
- Dimensions - Outdoor Unit WxDxH 770 × 300 × 555
- Net Weight Indoor / Outdoor 10.6 / 34.0 kg
- Refrigerant R22 / 720g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -
- Loading Quantities per 20’ / 40’HC 90 / 208
- MODEL O1CMI - 24 / O1CMO - 24
- Cooling Capacity 22.000 Btu / h
- Cooling Capacity 6.45 kWatt
- -
- Heating Capacity - kWatt
- EER 3.20 W / W
- COP - W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 9.5 A
- Current Input-Heating -
- Power Input-Cooling 2.014 W
- Power Input-Heating -
- Air Flow Volume (Hi / Med / Low) 960 / 770 / 680 m³ / h
- Noise Level-Indoor Unit 37.0 / 40.0 / 46.0 (db(A))
- Noise Level-Outdoor Unit 58.0
- Compressor Type ROTARY
- Liquid line / Gas line 3 / 8" / 5/8"
- Dimensions -Indoor Unit WxDxH 1.040 × 220 × 327 mm
- Dimensions - Outdoor Unit WxDxH 845 × 363 × 702
- Net Weight Indoor / Outdoor 13.6 / 45.5 kg
- Refrigerant R22 / 1.050g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -
- Loading Quantities per 20’ / 40’HC 66 / 154
Benefits
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

More
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
Louver Position Memory
Horizontal louver will automatically move to the same position as you set last time when the unit turned on
Refrigerant Leakage Detect
Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected
Auto Swing Louver
Distributes cool/warm air to maximum area by moving horizontal flaps automatically.
Two-way Draining
Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.