Core On / Off Heat Pump R410A

  • A Energy Class for a higher and more efficient performance
  • Blow Xfan eliminates unwanted moisture in the indoor unit
  • Achieve power saving and improved heating efficiency thanks to Intelligent Defrost

Become an Inventor Partner

  • MODEL RIMI - 09 / RIMO - 09
  • 9,000
  • Cooling Capacity 2.64 kWatt
  • 9,600
  • Heating Capacity 2.81 kWatt
  • EER 3.22 W / W
  • COP 3.61 W / W
  • Energy Class A / A
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 4.60 A
  • Current Input-Heating 5.10 A
  • Power Input-Cooling 821 W
  • Power Input-Heating 779 W
  • Air Flow Volume (Hi / Med / Low) 400 m³ / h
  • Noise Level-Indoor Unit 37 (db(A))
  • Noise Level-Outdoor Unit 50 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 3 / 8”
  • Dimensions -Indoor Unit WxDxH 730 × 255 × 174 mm
  • Dimensions - Outdoor Unit WxDxH 785 × 540 × 320 mm
  • Net Weight Indoor / Outdoor 8 / 32 kg
  • Refrigerant R410A / 760g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 116 / 280
  • MODEL R1IMI - 12 / R1IMO - 12
  • 11,000
  • Cooling Capacity 3.22 kWatt
  • 11,997
  • Heating Capacity 3.52 kWatt
  • EER 3.21 W / W
  • COP 3.62 W / W
  • Energy Class A / A
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 6.30 A
  • Current Input-Heating 6.10 A
  • Power Input-Cooling 1,004 W
  • Power Input-Heating 973 W
  • Air Flow Volume (Hi / Med / Low) 550 m³ / h
  • Noise Level-Indoor Unit 38 (db(A))
  • Noise Level-Outdoor Unit 52 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH 790 × 265 × 177 mm
  • Dimensions - Outdoor Unit WxDxH 798 × 540 × 320 mm
  • Net Weight Indoor / Outdoor 9 / 35 kg
  • Refrigerant R410A / 840g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 110 / 269
  • MODEL RIMI - 18 / RIMO - 18
  • 16,036
  • Cooling Capacity 4.70 kWatt
  • 16,720
  • Heating Capacity 4.90 kWatt
  • EER 3.22 W / W
  • COP 3.43 W / W
  • Energy Class A / B
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 10.00 A
  • Current Input-Heating 10.00 A
  • Power Input-Cooling 1,460 W
  • Power Input-Heating 1,430 W
  • Air Flow Volume (Hi / Med / Low) 850 m³ / h
  • Noise Level-Indoor Unit 45 (db(A))
  • Noise Level-Outdoor Unit 55 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH 940 × 298 × 200 mm
  • Dimensions - Outdoor Unit WxDxH 848 × 540 × 320 mm
  • Net Weight Indoor / Outdoor 10 / 40 kg
  • Refrigerant R410A / 1.150g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 87 / 210
  • MODEL RIMI - 24 / RIMO - 24
  • 21,000
  • Cooling Capacity 6.15 kWatt
  • 22,178
  • Heating Capacity 6.50 kWatt
  • EER 3.24 W / W
  • COP 3.42 W / W
  • Energy Class A / A
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 11.30 A
  • Current Input-Heating 11.70 A
  • Power Input-Cooling 1,900 W
  • Power Input-Heating 1,900 W
  • Air Flow Volume (Hi / Med / Low) 850 m³ / h
  • Noise Level-Indoor Unit 44 (db(A))
  • Noise Level-Outdoor Unit 56 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH 940 × 298 × 200 mm
  • Dimensions - Outdoor Unit WxDxH 913 × 680 × 378 mm
  • Net Weight Indoor / Outdoor 13 / 46 kg
  • Refrigerant R410A / 1.450g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 64 / 154

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Turbo Mode

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

Auto Error Diagnosis

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Auto Restart

Set the unit to start and stop automatically in a 24h period.

24-hour Timer

Distributes cool/warm air to maximum area by moving horizontal flaps automatically.

After setting the desired temperature, the unit will automatically adjust its operation in order to keep stable the temperature you have set

Horizontal louver will automatically move to the same position as you set last time when the unit turned on

Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation

Media Library for RIMI-RIMO air conditioners

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …