Features
Become an Inventor Partner
Specs
- MODEL RHSI - 09 / RHSO - 09
- 9,000
- Cooling Capacity 2.64 kWatt
- 9,600
- Heating Capacity 2.81 kWatt
- EER 2.61 W / W
- COP 2.61 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 6.60 A
- Current Input-Heating 6.20 A
- Power Input-Cooling 1,010 W
- Power Input-Heating 1,078 W
- Air Flow Volume (Hi / Med / Low) 400 m³ / h
- Noise Level-Indoor Unit 37 (db(A))
- Noise Level-Outdoor Unit 50 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 3 / 8”
- Dimensions -Indoor Unit WxDxH 730 × 255 × 174 mm
- Dimensions - Outdoor Unit WxDxH 720 × 430 × 310 mm
- Net Weight Indoor / Outdoor 8 / 27 kg
- Refrigerant R22 / 590g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 150 / 350
- MODEL RHSI - 12 / RHSO - 12
- 11,000
- Cooling Capacity 3.22 kWatt
- 11,500
- Heating Capacity 3.37 kWatt
- EER 2.61 W / W
- COP 2.89 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 6.30 A
- Current Input-Heating 6.30 A
- Power Input-Cooling 1,235 W
- Power Input-Heating 1,165 W
- Air Flow Volume (Hi / Med / Low) 550 m³ / h
- Noise Level-Indoor Unit 38 (db(A))
- Noise Level-Outdoor Unit 52 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 1 / 2”
- Dimensions -Indoor Unit WxDxH 790 × 265 × 177 mm
- Dimensions - Outdoor Unit WxDxH 772 × 540 × 320 mm
- Net Weight Indoor / Outdoor 9 / 32 kg
- Refrigerant R22 / 870g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 110 / 269
- MODEL RHSI - 18 / RHSO - 18
- 15,354
- Cooling Capacity 4.50 kWatt
- 16,378
- Heating Capacity 4.8 kWatt
- EER 2.50 W / W
- COP 2.67 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 12.10 A
- Current Input-Heating 10.30 A
- Power Input-Cooling 1,800 W
- Power Input-Heating 1,800 W
- Air Flow Volume (Hi / Med / Low) 650 m³ / h
- Noise Level-Indoor Unit 43 (db(A))
- Noise Level-Outdoor Unit 57 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 1 / 2”
- Dimensions -Indoor Unit WxDxH 845 × 275 × 186 mm
- Dimensions - Outdoor Unit WxDxH 848 × 540 × 320 mm
- Net Weight Indoor / Outdoor 10 / 42 kg
- Refrigerant R22 / 1.040g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 101 / 244
- MODEL RHSI - 24 / RHSO - 24
- 21,000
- Cooling Capacity 6.16 kWatt
- 22,860
- Heating Capacity 6.7 kWatt
- EER 2.74 W / W
- COP 2.98 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 13.70 A
- Current Input-Heating 12.95 A
- Power Input-Cooling 2,250 W
- Power Input-Heating 2,250 W
- Air Flow Volume (Hi / Med / Low) 850 m³ / h
- Noise Level-Indoor Unit 45 (db(A))
- Noise Level-Outdoor Unit 57 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 1 / 2”
- Dimensions -Indoor Unit WxDxH 940 × 298 × 200 mm
- Dimensions - Outdoor Unit WxDxH 955 × 700 × 424 mm
- Net Weight Indoor / Outdoor 13 / 56 kg
- Refrigerant R22 / 1.510g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 60 / 149
Benefits
Turbo Mode
This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

24-hour Timer
Set the unit to start and stop automatically in a 24h period.

Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

More
Auto Swing Louver
Distributes cool/warm air to maximum area by moving horizontal flaps automatically.
Automatic Operation
After setting the desired temperature, the unit will automatically adjust its operation in order to keep stable the temperature you have set
Louver Position Memory
Horizontal louver will automatically move to the same position as you set last time when the unit turned on
Two-way Draining
Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.