Cassettes air conditioners. The absolute solution for business environments with low height

  • Excellent protection of the unit due to the protection of the golden fin
  • The air outlet from 8 points offers high levels of comfort and efficiency
  • Enjoy a clean and healthy atmosphere due to the fresh inlet air
  • Take advantage of the upgraded indoor unit’s design and achieve cooling in one more room
  • Enjoy even more functions and operations thanks to the wide range of central controllers
  • Enjoy a clean and healthy atmosphere by introducing fresh air into the room
  • Enjoy extra features and functions through a wide range of central controls
  • Flexibility even in the most demanding installations thanks to the built-in condensate pump
  • Check the air conditioner wherever you are thanks to the Wi-Fi remote management and create the ideal conditions in your space

Become an Inventor Partner

  • MODEL V6MCRI32-18WiFiR/U6MRS32-18
  • Cooling Capacity 18.000 Btu / h
  • Heating Capacity 18.500 Btu / h
  • Cooling Capacity Range (9.900-19.600) Btu / h
  • Cooling Capacity Range 5.28 (2.90-5.74) kWatt
  • Heating Capacity (8.100-20.800) Btu / h
  • Heating Capacity 5.42 (2.37-6.09) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 5.3 kW
  • Energy Class A++ kW
  • SEER 6.1
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 4.2 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 5.3 kW
  • Energy Class A++ kW
  • SCOP 4.9
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling / Heating 3.2-8.2/3.1-8.5 A
  • Power Input Cooling / Heating 720-1.860/700-1.930 W
  • Air Flow Volume 720/625/540 High / Medium / Low
  • Noise Level Indoor unit 35.5/39/42.5 Low / Medium / High
  • Noise Level Outdoor unit 57 dB
  • Sound Power Level Indoor / Outdoor unit 56/63 dB
  • Power Supply Wire Outdoor / Fuses ( 3x2.5/1x16 No x mm2 / A
  • Signal Wires 3 x 1.5 & (2 x 1.0 Shield) No x mm2
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 570x570x260 mm
  • Dimensions WxDxH Outdoor unit 800x333x554 mm
  • Net Weight Panel / Indoor / Outdoor 2.5/16.2/33.7 kg
  • Liquid line - Gas line 1/4"/1/2" °C
  • Refrigerant / Charge R32/1.350 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 oC
  • MODEL V5MCI32-24WiFiR/U5MRS32-24
  • Cooling Capacity 24.000 Btu / h
  • Heating Capacity 26.000 Btu / h
  • Cooling Capacity Range (10.990-28.000) Btu / h
  • Cooling Capacity Range 7.03 (3.22-8.21) kWatt
  • Heating Capacity (8.300-29.500) Btu / h
  • Heating Capacity 7.62 (2.43-8.65) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 7.0 kW
  • Energy Class A++ kW
  • SEER 6.1
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 5.4 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 5.8 kW
  • Energy Class A++ kW
  • SCOP 4.9
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling / Heating 2.1-12.4/2.2-12.5 A
  • Power Input Cooling / Heating 480-2.850/500-2.880 W
  • Air Flow Volume 1.378/1.200/1.032 High / Medium / Low
  • Noise Level Indoor unit 40/43/47 Low / Medium / High
  • Noise Level Outdoor unit 62 dB
  • Sound Power Level Indoor / Outdoor unit 59/64 dB
  • Power Supply Wire Outdoor / Fuses ( 3x2.5/1x16 No x mm2 / A
  • Signal Wires 3 x 1.5 & (2 x 1.0 Shield) No x mm2
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 840x840x205 mm
  • Dimensions WxDxH Outdoor unit 845x363x702 mm
  • Net Weight Panel / Indoor / Outdoor 5/23/66.8 kg
  • Liquid line - Gas line 3/8"/5/8" °C
  • Refrigerant / Charge R32/1.500 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 oC
  • MODEL V5MCI32-36WiFiR/U5MRS32-36
  • Cooling Capacity 36.000 Btu / h
  • Heating Capacity 38.000 Btu / h
  • Cooling Capacity Range (13.800-41.000) Btu / h
  • Cooling Capacity Range 10.55 (4.04-12.02) kWatt
  • Heating Capacity (10.050-46.000) Btu / h
  • Heating Capacity 11.14 (2.94-13.48) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 10.5 kW
  • Energy Class A++ kW
  • SEER 6.1
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 8.8 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 10.5 kW
  • Energy Class A++ kW
  • SCOP 4.9
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling / Heating 3.9-19.6/3.2-19.4 A
  • Power Input Cooling / Heating 890-4.500/720-4.550 W
  • Air Flow Volume 1.775/1.620/1.438 High / Medium / Low
  • Noise Level Indoor unit 46/49/51 Low / Medium / High
  • Noise Level Outdoor unit 65 dB
  • Sound Power Level Indoor / Outdoor unit 61/66 dB
  • Power Supply Wire Outdoor / Fuses ( 3x4.0/1x25 No x mm2 / A
  • Signal Wires 3 x 1.5 & (2 x 1.0 Shield) No x mm2
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 840x840x245 mm
  • Dimensions WxDxH Outdoor unit 946x410x810 mm
  • Net Weight Panel / Indoor / Outdoor 5/27.5/66.8 kg
  • Liquid line - Gas line 3/8"/5/8" °C
  • Refrigerant / Charge R32/2.400 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 oC
  • MODEL V5MCI32-50WiFiR/U5MRT32-50
  • Cooling Capacity 48.000 Btu / h
  • Heating Capacity 55.000 Btu / h
  • Cooling Capacity Range (16.224-49.761) Btu / h
  • Cooling Capacity Range 14.07 (4.76-14.58) kWatt
  • Heating Capacity (13.396-57.206) Btu / h
  • Heating Capacity 16.12 (3.93-16.77) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 14.0 kW
  • Energy Class A++ kW
  • SEER 6.1
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 11.2 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 12.5 kW
  • Energy Class A++ kW
  • SCOP 4.8
  • Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
  • Current Input Cooling / Heating 1.8-9.26/1.56-8.83 A
  • Power Input Cooling / Heating 1.174-5.602/987-5.378 W
  • Air Flow Volume 1.715/1.568/1.381 High / Medium / Low
  • Noise Level Indoor unit 49/50/52 Low / Medium / High
  • Noise Level Outdoor unit 66 dB
  • Sound Power Level Indoor / Outdoor unit 65/72 dB
  • Power Supply Wire Outdoor / Fuses ( 5x2.5/3x20 No x mm2 / A
  • Signal Wires 3 x 1.5 & (2 x 1.0 Shield) No x mm2
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 840x840x287 mm
  • Dimensions WxDxH Outdoor unit 952x415x1.333 mm
  • Net Weight Panel / Indoor / Outdoor 5/29/106.7 kg
  • Liquid line - Gas line 3/8"/5/8" °C
  • Refrigerant / Charge R32/2.800 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 oC
  • MODEL V5MCI32-60WiFiR/U5MRT32-60
  • Cooling Capacity 53.000 Btu / h
  • Heating Capacity 62.000 Btu / h
  • Cooling Capacity Range (18.000-57.000) Btu / h
  • Cooling Capacity Range 15.8 (5.28-16.71) kWatt
  • Heating Capacity (15.000-66.000) Btu / h
  • Heating Capacity 18.2 (4.4-19.34) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 15.7 kW
  • Energy Class A++ kW
  • SEER 6.1
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 11.9 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 12.5 kW
  • Energy Class A+++ kW
  • SCOP 5.1
  • Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
  • Current Input Cooling / Heating 1.8-11.6/1.6-11.2 A
  • Power Input Cooling / Heating 1.147-6.682/1.022~6.448 W
  • Air Flow Volume 1.970/1737/1.537 High / Medium / Low
  • Noise Level Indoor unit 48/50.5/53 Low / Medium / High
  • Noise Level Outdoor unit 66 dB
  • Sound Power Level Indoor / Outdoor unit 62/65 dB
  • Power Supply Wire Outdoor / Fuses ( 5x2.5/3x20 No x mm2 / A
  • Signal Wires 3 x 1.5 & (2 x 1.0 Shield) No x mm2
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 840x840x287 mm
  • Dimensions WxDxH Outdoor unit 952x415x1.333 mm
  • Net Weight Panel / Indoor / Outdoor 5/29.7/111.3 kg
  • Liquid line - Gas line 3/8"/5/8" °C
  • Refrigerant / Charge R32/2.950 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50 / -15~24 oC

The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.

Low Ambient Cooling

This feature refers to the reduced noise emissions in order to achieve a pleasant and comfortable unit operation. The special design of the indoor unit οffers excellent performance at the lowest noise level, so that to enjoy ideal conditions of absolute silence.

Take the whole control of you unit! Thanks to the error code that will appear if an error occurs, you can always be safe and sure for the appropriate and most efficient operation of your air conditioner.

Error Alarm Port

With a smart control board, air conditioners can be turned on/off via long distance control signals.

Front Desk Control On/Off(Optional)

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Auto Restart

Set the unit to start and stop automatically in a 24h period.

24-hour Timer

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation

The perceived temperature by the indoor unit sensor may vary from the real temperature of the room, due to the position of the unit. Thanks to this function you can minimize the difference and achieve better conditions in your place.

With the On / Off switch, you can choose whether you want the fan to continue operating after the unit is turned off or stop.

Due to the independent electronic valve, Inventor air conditioners guarantee outstanding performance and excellent control of your systems. Create and enjoy the desired atmosphere in you place!

Due to the DC fan motor, outdoor fan speeds increase from 2 grades to 5 grades, more comfortable and reinforces energy saving.

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

The advanced electronic board of Inventor air conditioners includes outputs, through which you can receive a warning signal, in case of unit’s malfunction or abnormal operation (light indication).

Take advantage of the 4 choices to adjust the indoor unit’s fan speed and benefit from the Filter Cleaning Reminder mode, the Louver Position Memory, the Temperature Compensation sensor and the Higher/ Lower Temperature settings to create the ideal conditions in your place.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

Media Library for Cassettes

User & Installation Manuals - Energy Labels - Pdesign Test Report - High Resolution Photos

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …